{"title":"Natural Gas Heaters \u0026 Parts","description":"\u003cp\u003eNatural gas pool and spa heaters and natural gas heater parts.\u003c\/p\u003e","products":[{"product_id":"pentair-natural-gas-millivolt-pilot-with-blue-spark-wire-for-minimax-minimax-ch-and-plus-471292","title":"Pentair 471292 Natural Gas Millivolt Pilot with Blue Spark Wire for MiniMax, MiniMax CH and MiniMax Plus Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e471292\u003c\/strong\u003e: Natural Gas Millivolt Pilot with Blue Spark Wire.\u003c\/p\u003e\n\u003cp\u003eA replacement natural gas millivolt pilot for Pentair MiniMax CH and MiniMax Plus heaters.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e471292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Pentair)\u003c\/th\u003e\n\u003ctd\u003ePilot, natural, millivolt, includes blue spark wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003ePentair MiniMax CH and MiniMax Plus heater models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379696238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair MiniMax Plus Heater Replacement Parts p. 3; Pentair Heater and Heat Pump Parts 2020 p. 439, 441; Pentair Heater and Heat Pump Parts 2019 p. 443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003ePentair 471292 Pilot, Pentair Minimax\/Minimax Plus, Nat., Millivolt\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis part fits on the following heaters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePentair Minimax CH Heater\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":42915330195675,"sku":"471292","price":72.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/products\/Pentair-471292.jpg?v=1652293032"},{"product_id":"pentair-air-pressure-switch-green-for-minimax-nt-std-and-low-nox-250-300-heaters-472180","title":"Pentair 472180 Air Pressure Switch, Green, for MiniMax NT STD and Low NOx 250\/300 Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e472180\u003c\/strong\u003e: Air Pressure Switch, Green. A replacement air pressure switch for MiniMax NT heaters, chosen by heater model number and installation elevation in Pentair's air pressure switch table.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e472180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Pentair)\u003c\/th\u003e\n\u003ctd\u003eAir pressure switch, color setting Green (Air Pressure Switches table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003e460559 NT STD ASME Nat 250, 3000-5999 ft.; 460553 NT STD ASME Nat 300, 3000-5999 ft.; 460558 NT STD LP 250, 3000-5999 ft.; 460552 NT STD LP 300, 3000-5999 ft.; 460560 NT STD ASME LP 250, 3000-5999 ft.; 460554 NT STD ASME LP 300, 3000-5999 ft.; 460574 NT Low NOx ASME Nat 300, 3000-5999 ft.; 460576 NT Low NOx Nat 250, 0-2999 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379715540\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair Heater and Heat Pump Parts 2020 p. 444; Pentair Heater and Heat Pump Parts 2019 p. 448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":42915323379931,"sku":"472180","price":78.89,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/products\/pentair-472180.jpg?v=1652293094"},{"product_id":"raypak-natural-gas-millivolt-pilot-with-generator-for-206a-266-266a-336a-399-406a-rp2100-600525b","title":"Raypak 600525B Natural Gas Millivolt Pilot with Generator for 206A, 266\/266A, 336A, 399\/406A, RP2100 R185A-R405A, R185B-R405B, Versa 130A Pool Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e600525B\u003c\/strong\u003e: Natural gas millivolt pilot.\u003c\/p\u003e\n\u003cp\u003eA replacement natural gas pilot for the millivolt (MV) versions of Raypak 206A-406A, RP2100 and Versa 130A pool heaters.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e600525B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003ePilot Nat. MV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits Raypak models\u003c\/th\u003e\n\u003ctd\u003e206A, 266\/266A, 336A, 399\/406A; RP2100 185A, 265A, 335A, 405A; RP2100 185B, 265B, 335B, 405B; Versa 130A (Green and Cool Dark Gray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e662766418989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 24; Raypak IPL 9100.56 Millivolt 206A-406A p. 7; Raypak IPL 9100.554 RP2100 R185A-R405A p. 5; Raypak IPL 9100.555 RP2100 R185B-R405B p. 5; Raypak IPL 9100.21 Versa 130A p. 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis is the standing pilot burner for Raypak millivolt heaters that run on natural gas. On these heaters the pilot burns all the time and also acts as a safety: if the pilot flame goes out, gas to the pilot and the main burners shuts off until the pilot is relit by hand.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAdditional Raypak millivolt models:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e206A to 406A millivolt heaters built from October 2004. Digital models use a different pilot.\u003c\/li\u003e\n\u003cli\u003eRP2100 millivolt heaters R185, R265, R335, R405 (1993 to 1998)\u003c\/li\u003e\n\u003cli\u003eVersa 185A to 405A (1986 to 1988) and Versa 185B to 405B (1988 to 1993) millivolt heaters\u003c\/li\u003e\n\u003cli\u003eVersa 155A (1987 to 1991), Versa 155B\/C (1991 to 2006), Versa 105A (1991 to 1999) and Versa 105B (1999 to 2006)\u003c\/li\u003e\n\u003cli\u003eVersa 055A (1987 to 1989) and Versa 055B (1990 to 2013)\u003c\/li\u003e\n\u003cli\u003eSpa-Pak 053A and 053B (1984 to 1987), Gemini and Spa-Pak 153A (1984 to 1987) and 153 (1981 to 1984), Spa-Pak and California III 151 (1974 to 1981)\u003c\/li\u003e\n\u003cli\u003eGemini and Spa-Pak 183A, 263A, 333A, 403A (1984 to 1986) and Gemini 181, 261, 331, 401 (1974 to 1982) with a standing pilot\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eRaypak's parts-library photo shows the pilot burner with the pilot generator (thermopile) and its armored lead attached, plus two mounting screws. Sold separately on the same parts lists: pilot generator 600019B, natural gas pilot orifice 003901F and pilot tube 004078F. The propane version of this pilot is 600575B. Electronic-ignition (IID) versions of these heaters use a different pilot.\u003c\/p\u003e\u003cp\u003ePilot and gas work should be done by a qualified service technician.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":42915381641435,"sku":"600525B","price":93.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/products\/51CtXvrLs0L._AC.jpg?v=1665608069"},{"product_id":"raypak-pilot-natural-and-propane-iid-for-206a-266-266a-336a-399-406a-408a-r185a-r405a-r185b-002003f","title":"Raypak 002003F Pilot Natural and Propane IID for 206A, 266\/266A, 336A, 399\/406A, 408A, R185A-R405A, R185B-R405B Pool Heaters, 106A, 156A","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e002003F\u003c\/strong\u003e: Pilot Natural and Propane IID kit, for electronic ignition heaters. A pilot assembly kit for Raypak electronic ignition (IID) pool heaters that run on natural gas or propane.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e002003F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003ePilot Nat \u0026amp; Pro IID (KIT-PILOT E10 NAT\/PRO 053-408); for RP2100 185A-405A, built after 06\/01\/2000: Pilot IID Atmospheric (includes nat \u0026amp; pro orifice)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits Raypak models\u003c\/th\u003e\n\u003ctd\u003e206A, 266\/266A, 336A, 399\/406A, 408A, RP2100 185A, 265A, 335A, 405A, RP2100 185B, 265B, 335B, 405B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplaces\u003c\/th\u003e\n\u003ctd\u003e002064F (KIT-PILOT 055-403 E11 PRO); 007864F (KIT-WIRE HIGH TENSION W\/ELECTRODE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e662766384376\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 24, 45; Raypak IPL 9100.56 Millivolt 206A-406A p. 7; Raypak IPL 241452 Pro Series 268A, 408A p. 44; Raypak IPL 9100.554 RP2100 R185A-R405A p. 5; Raypak IPL 9100.555 RP2100 R185B-R405B p. 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with listed Raypak electronic heater models\u003c\/li\u003e\n\u003cli\u003eIncludes pilot sized for natural or propane service\u003c\/li\u003e\n\u003cli\u003eConvertible between natural gas and propane by changing orifice\u003c\/li\u003e\n\u003cli\u003ePropane orifice identified by red dot or smaller size\u003c\/li\u003e\n\u003cli\u003eDoes not include pilot tube or wire harness\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eAlso fits 106A, 156A and the Versa and Spa-Pak IID heaters: Versa 185A to 405A (1986 to 1988), Versa 185B to 405B (1988 to 1992), Versa 055A (1987 to 1989), Versa 055B (1990 to 2013), Versa 105A (1991 to 1999), Versa 105B (1999 to 2006), Spa-Pak 053A and 053B (1984 to 1987).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNot for Low NOx heaters (207A to 407A use Raypak 010232F) or for millivolt (standing pilot) heaters, which use 600525B on natural gas and 600575B on propane.\u003c\/li\u003e\n\u003cli\u003eRP2100 units built before June 1, 2000 use pilot 008668F.\u003c\/li\u003e\n\u003cli\u003ePilot orifices are listed separately: 003903F (natural gas, .020) and 004308F (propane, .012).\u003c\/li\u003e\n\u003cli\u003ePilot and gas train work is for a qualified gas technician.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":42915381575899,"sku":"002003F","price":69.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/products\/pilotnatural.jpg?v=1665607894"},{"product_id":"073727-pentair-minimax-ng-main-burner-orifice-green","title":"Pentair 073727 Main Burner Orifice No. 30, Natural Gas, Green, for MiniMax Plus, NT STD and CH Heaters (0-2999 ft.) - Discontinued - Limited Qty","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003e\u003cstrong\u003eDiscontinued - Limited Qty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e073727\u003c\/strong\u003e: Main Burner Orifice No. 30, Natural Gas, Green, 0-2999 ft.\u003c\/p\u003e\n\u003cp\u003eA replacement natural gas main burner orifice for Pentair MiniMax heaters at a specified altitude of 0-2999 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e073727\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Pentair)\u003c\/th\u003e\n\u003ctd\u003eOrifice main burner, natural. Natural gas heater orifice chart: Orifice No. 30, Orifice Dia. .1285, Color Green, Specified altitude 0–2999 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eMiniMax Plus; NT STD (natural gas, 0–2999 ft.); CH (natural gas, 0–2999 ft.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379696337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair MiniMax Plus Heater Replacement Parts p. 3; Pentair Heater and Heat Pump Parts 2020 p. 445, 447; Pentair Heater and Heat Pump Parts 2019 p. 449\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eBrass construction. Replace the orifice if it is clogged, worn or shows signs of corrosion.\u003c\/p\u003e\u003cp\u003eInstallation should be performed by a qualified technician. Turn off the gas supply and follow all safety procedures in your heater's manual before servicing.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":43535127773403,"sku":"073727","price":8.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/products\/26858419-1.jpg?v=1666382113"},{"product_id":"460743-pentair-mastertemp-air-blower-kit-natural-gas-units-250na","title":"Pentair 460743 Air Blower Kit for MasterTemp 250NA Natural Gas Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e460743\u003c\/strong\u003e: Air Blower Kit, Natural Gas, 250NA. A replacement combustion air blower kit for natural gas heater units, Models 250NA.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e460743\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Pentair)\u003c\/th\u003e\n\u003ctd\u003eAir Blower Kit - Natural Gas Units (Models 250NA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003ctd\u003eModels 250NA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379726669\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair Heater and Heat Pump Replacement Parts 2025-2026 p. 383; Pentair Heater and Heat Pump Parts 2024 p. 450; Pentair Heater and Heat Pump Parts 2020 p. 430; Pentair Heater and Heat Pump Parts 2019 p. 434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eFits Pentair MasterTemp 250NA natural gas pool heaters. Check your heater model number to ensure correct fit.\u003c\/p\u003e\u003cp\u003eIf you need help finding the right replacement kit for your Pentair heater, our team is ready to assist you.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":43552561004763,"sku":"460743","price":700.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/products\/51mAT9Vi-TL._AC_SL1000.jpg?v=1679595723"},{"product_id":"raypak-digital-p-r406a-en-c-50-pool-heater-natural-gas-399-000-btu-copper-heat-exchanger-0-009219","title":"Raypak 009219 Digital P-R406A-EN-C #50 Pool Heater, Natural Gas, 399,000 BTU, Copper Heat Exchanger, 0-2000 ft","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e009219\u003c\/strong\u003e: Digital P-R406A-EN-C #50 pool heater, natural gas, 399,000 BTU. A natural gas pool heater with digital control, electronic ignition, polymer headers and copper tubing, listed by Raypak for elevations from 0 to 2000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e009219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eP-R406A-EN-C #50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eDigital with Polymer Headers, Copper Tubing, Electronic Ignition, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891012788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e399,000 BTU\/h (116.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e249 (w\/Stackless Top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRheem equivalent\u003c\/th\u003e\n\u003ctd\u003eP-M406A-EN-C #50, part 009965\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 13, 93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDigital control\u003c\/li\u003e\n\u003cli\u003eElectronic ignition\u003c\/li\u003e\n\u003cli\u003ePolymer headers\u003c\/li\u003e\n\u003cli\u003eCopper tubing heat exchanger\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eRaypak lists the propane 406A for the same elevation as item 009227, item 009223 for 2,000 to 6,000 ft and item 009849 for 6,000 to 9,000 ft.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009841 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 40 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eRaypak lists the Digital series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield sacrificial assembly under the inlet connection protects the heat exchanger from galvanic corrosion. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eLCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 29 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 9 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: two years parts and labor, or one year when installed anywhere other than a single-family home. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003cli\u003eRuud cross-reference: Ruud item 009997, model P-D406A-EN-C #50.\u003c\/li\u003e\n\u003cli\u003eAbove 2,000 ft the manual reduces input 4% for each 1,000 ft above sea level.\u003c\/li\u003e\n\u003cli\u003eThis is an atmospheric heater, not a Low NOx model. Raypak's Low NOx Digital heaters are the 207A to 407A models, and some states and localities require Low NOx heaters.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer and meet local codes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061942251739,"sku":"009219","price":4426.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/51sPMRI0_lL.jpg?v=1744032652"},{"product_id":"raypak-above-ground-p-r106a-an-c-pool-heater-natural-gas-0-4999-ft-copper-polymer-headers-014779","title":"Raypak 014779 Above Ground P-R106A-AN-C Pool Heater, Natural Gas, 0-4999 ft, Copper, Polymer Headers, Analog Control, Rheem 014797","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e014779\u003c\/strong\u003e: Above Ground P-R106A-AN-C Pool Heater, Natural Gas, 0-4999 ft.\u003c\/p\u003e\n\u003cp\u003eA natural gas pool and spa heater with polymer headers, copper tubing, analog control and electronic ignition, for installations from 0 to 4999 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e014779\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eP-R106A-AN-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003ePolymer Headers, Analog Control, Electronic Ignition, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891034223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-4999 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper tubing, polymer headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e85 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 59, 93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak 106A is a compact atmospheric gas heater for above-ground pools and spas, rated at 105,000 BTU per hour on natural gas. It is the analog model in the Above Ground series: an on\/off switch and a thermostat dial instead of a digital display. It ships with a 120 V power cord and a stackless top for outdoor installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNatural gas only. The propane 106A is a different item number (014781 for 0 to 1,999 ft).\u003c\/li\u003e\n\u003cli\u003eRaypak lists item 014780 for 5,000 to 9,999 ft.\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top. Indoor installation needs Raypak drafthood kit 014357 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 20 and 70 GPM. Above 70 GPM Raypak requires an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eRaypak states the Above Ground series cannot be sold in Low NOx markets, including Southern California and Utah.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eInput rating 105,000 BTU\/hr (30.75 kW). Raypak lists the Above Ground series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eAnalog control: an on\/off switch and a thermostat dial on the upper front panel. Setpoint range 65 F to 104 F, with an adjustable knob stop to cap the maximum.\u003c\/li\u003e\n\u003cli\u003eSpark-to-pilot electronic ignition. The pilot is lit automatically and the main gas valve opens only after the pilot flame is proven.\u003c\/li\u003e\n\u003cli\u003eStainless steel tube sheets, with a built-in automatic bypass valve.\u003c\/li\u003e\n\u003cli\u003eShips with a 120 VAC three-prong cord; the transformer can be rewired for 240 VAC. Draws 4 A at 120 V or 2 A at 240 V. Raypak requires a grounded, GFCI-protected supply.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. CPVC unions. Gas connection 1\/2 in. NPT. Cabinet depth 24 in. Flue diameter 6 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: two 2 in. CPVC unions with O-rings, plastic finish flange for the gas line, bonding lug and the manual. The outdoor stackless top is standard with the unit.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: two years parts and labor.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 014797, model P-M106A-AN-C, is the same heater sold under the Rheem label.\u003c\/li\u003e\n\u003cli\u003eRuud cross-reference: Ruud item 014815, model P-D106A-AN-C, is the same heater sold under the Ruud label.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe 106A is not equipped for remote operation; in this series only the digital 156A is.\u003c\/li\u003e\n\u003cli\u003eThe heater must sit at least 5 ft from the inside wall of the pool unless a solid fence, wall or other permanent barrier separates them.\u003c\/li\u003e\n\u003cli\u003eIt can be installed on combustible flooring, but not on carpet.\u003c\/li\u003e\n\u003cli\u003eFor sites with frequent high wind Raypak offers an optional outdoor stack, part 014718.\u003c\/li\u003e\n\u003cli\u003eRaypak reduces the input 4% for each 1,000 ft above sea level when the heater is installed above 2,000 ft.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061948510427,"sku":"014779","price":2119.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/shopping_e098ad5d-4db4-4f31-be33-391d3ef4b044.webp?v=1734478121"},{"product_id":"raypak-pilot-334-4000-e10-natural-gas-kit-for-raytherm-334-824-and-926-1826-commercial-002234f","title":"Raypak 002234F Pilot 334-4000 E10 Natural Gas Kit for Raytherm 334-824 and 926-1826 Commercial Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e002234F\u003c\/strong\u003e: Pilot 334-4000 E10 Natural Gas Kit.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e002234F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e662766386790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis is the natural gas pilot burner for Raypak Raytherm commercial heaters with intermittent ignition (IID), the system that lights the pilot by spark instead of leaving it burning.\u003c\/p\u003e\u003cp\u003eThe propane pilot for the same heaters is 002235F. Not for Raypak residential heaters. Pilot and gas-train work should be done by a qualified service technician.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061957587163,"sku":"002234F","price":80.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/JP2234F44_1-B.jpg?v=1721587549"},{"product_id":"raypak-digital-p-r336a-en-c-50-pool-heater-natural-gas-332-500-btu-copper-heat-exchanger-009218","title":"Raypak 009218 Digital P-R336A-EN-C #50 Pool Heater, Natural Gas, 332,500 BTU, Copper Heat Exchanger","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e009218\u003c\/strong\u003e: Digital P-R336A-EN-C #50 natural gas pool heater, 332,500 BTU. A natural gas pool and spa heater with a copper heat exchanger, rated at 332,500 BTU\/h input for installations from 0 to 2,000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e009218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eP-R336A-EN-C #50, Copper Heat Exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891012771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e332,500 BTU\/h (332.5 MBTUH, 97.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e230 lb w\/Stackless Top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital 336A is an atmospheric gas heater for pools and spas, with polymer headers, electronic ignition and a digital thermostat with an LCD display.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNatural gas only. The propane 336A for the same elevation is a different item number (009226).\u003c\/li\u003e\n\u003cli\u003eRaypak lists item 009222 for 2,000 to 6,000 ft and item 009848 for 6,000 to 9,000 ft.\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009840 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 35 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield sacrificial assembly under the inlet connection protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 26 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 8 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: two years parts and labor.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 009964, model P-M336A-EN-C #50, is the same heater sold under the Rheem label.\u003c\/li\u003e\n\u003cli\u003eRuud cross-reference: Ruud item 009996, model P-D336A-EN-C #50, is the same heater sold under the Ruud label.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAbove 2,000 ft the manual reduces input 4% for each 1,000 ft above sea level, and Raypak sells separate versions of this heater for higher elevations.\u003c\/li\u003e\n\u003cli\u003eThis is an atmospheric heater, not a Low NOx model. Raypak's Low NOx Digital heaters are the 207A to 407A models, and Raypak notes that some states and localities require Low NOx heaters.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061957947611,"sku":"009218","price":3841.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/51O-13g8SkL._AC_UF894_1000_QL80.jpg?v=1721587442"},{"product_id":"raypak-avia-p-r404a-en-c-pool-heater-natural-gas-399-000-btu-copper-heat-exchanger-wi-fi-018033","title":"Raypak 018033 Avia P-R404A-EN-C Pool Heater, Natural Gas, 399,000 BTU, Copper Heat Exchanger, Wi-Fi, Rheem 018069","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e018033\u003c\/strong\u003e: Avia P-R404A-EN-C Pool Heater, Natural Gas, 399,000 BTU, Copper Heat Exchanger.\u003c\/p\u003e\n\u003cp\u003eA Low NOx Avia gas pool heater with polymer headers and copper tubing, for natural gas installations from 0 to 10,000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e018033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eP-R404A-EN-C, Low NOx AVIA Pool Heater with Polymer Headers, Copper Tubing, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891047292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e399,000 BTU\/h (116.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e155 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 1, 93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow NOx\u003c\/li\u003e\n\u003cli\u003ePolymer headers\u003c\/li\u003e\n\u003cli\u003eCopper tubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Avia 404A is the larger of the two Avia sizes. Wi-Fi is built into the control, so the heater can be set and watched from the Raymote phone app with no separate control panel. This version has the copper straight-tube heat exchanger and is rated at 84% thermal efficiency.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNatural gas (certified to 4,500 ft; above that a qualified technician adjusts the gas valve)\u003c\/li\u003e\n\u003cli\u003eResidential pools and spas on 2 in. plumbing, with 40 to 100 GPM of flow through the heater\u003c\/li\u003e\n\u003cli\u003eOutdoor pads using the vent cap supplied with the heater, or indoor and direct-vent installations with the venting Raypak specifies in the manual\u003c\/li\u003e\n\u003cli\u003eReplacing an older heater: Raypak laid out the water and gas connections to line up with common heaters, and the cabinet is about 23 in. square (Raypak calls it a 2x2 footprint)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSupply pressure 3.5 in. WC minimum while firing, 10.5 in. WC maximum static.\u003c\/li\u003e\n\u003cli\u003eStraight-tube heat exchanger with a polymer inlet\/outlet header and a stainless steel combustion chamber.\u003c\/li\u003e\n\u003cli\u003eWater connections: 2 in. Two 2 in. CPVC tailpieces with ring nuts and O-rings come in the carton.\u003c\/li\u003e\n\u003cli\u003eGas connection: 3\/4 in. NPT. Flue: 4 in.\u003c\/li\u003e\n\u003cli\u003ePower: 240 V as shipped, convertible to 120 V, single phase, 60 Hz. Draws about 1.2 A at 240 V or 1.6 A at 120 V. Not for 208 V.\u003c\/li\u003e\n\u003cli\u003eControl: touchpad with LCD display, pool and spa modes, and Wi-Fi for the Raymote app. A 3-wire remote harness is included for automation systems, and the control can run a Raypak Protege or AquaStar Smart variable-speed pump.\u003c\/li\u003e\n\u003cli\u003eProTek Shield module on the water inlet protects the heat exchanger from galvanic corrosion (replacement module 017960F).\u003c\/li\u003e\n\u003cli\u003eCabinet: 23.24 in. wide x 23.22 in. deep x 30.38 in. high, not counting the outdoor vent cover on one side and the water header on the other. Unit weight 135 lb.\u003c\/li\u003e\n\u003cli\u003eAlso in the carton: 120 V blower adapter, auxiliary harness and Raymote quick start guide.\u003c\/li\u003e\n\u003cli\u003eCertified to ANSI Z21.56 \/ CSA 4.7, SCAQMD Rule 1146.2 and SJVAPCD Rule 4308.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: 3 years parts and labor when installed by a licensed installer at a single-family home; 1 year in any other setting.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 018069, model P-M404A-EN-C, is the same heater sold under the Rheem label.\u003c\/li\u003e\n\u003cli\u003eRuud cross-reference: Ruud item 018093, model P-D404A-EN-C, is the same heater sold under the Ruud label.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe ProTek Shield is a wear part. Raypak says to replace it once it is down to about 40% of its original weight.\u003c\/li\u003e\n\u003cli\u003eRaypak requires a sediment trap on the gas line.\u003c\/li\u003e\n\u003cli\u003eChlorinators and chemical feeders go downstream of the heater, with a check valve between them.\u003c\/li\u003e\n\u003cli\u003eKeep the heater at least 3 ft from a heat pump or outdoor condensing unit.\u003c\/li\u003e\n\u003cli\u003eConnecting to Raymote needs a reliable Wi-Fi signal at the equipment pad.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer and meet local codes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061981802715,"sku":"018033","price":4426.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/raypak-avia-digital-heater-copper-wifi-ready.jpg?v=1744032128"},{"product_id":"raypak-digital-asme-b-r406a-en-x-50-pool-heater-natural-gas-399-000-btu-cupronickel-bronze-017402","title":"Raypak 017402 Digital ASME B-R406A-EN-X #50 Pool Heater, Natural Gas, 399,000 BTU, Cupronickel, Bronze Headers","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017402\u003c\/strong\u003e: Digital ASME B-R406A-EN-X #50 pool heater, natural gas, 399,000 BTU. A natural gas pool and spa heater with a cupro-nickel heat exchanger, rated 399,000 BTU\/h input for installations from 0 to 2,000 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eB-R406A-EN-X #50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891042198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e399,000 BTU\/h (116.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCupro-Nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e269 lb with stackless top; indoor draft hood 21 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse: commercial pools and spas, and other installations where an ASME-certified heater is required. Raypak lists the propane version as item 017414, item 017406 for 2,000 to 6,000 ft and item 017410 for 6,000 to 9,000 ft. The same heater with copper tubes is Raypak item 017374.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009841 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 40 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eAtmospheric heater, not a Low NOx model. Raypak's Low NOx ASME heaters are the 207A to 407A series.\u003c\/li\u003e\n\u003cli\u003eRaypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eASME heat exchanger, HLW-stamped and National Board registered, 100 PSIG maximum allowable working pressure. Bronze headers, cupronickel fin tubes, steel tube sheets.\u003c\/li\u003e\n\u003cli\u003e75 PSI pressure relief valve included, shipped loose in the accessory carton; the header has a 3\/4 in. NPT connection for it.\u003c\/li\u003e\n\u003cli\u003eProTek Shield sacrificial assembly with its adapter, packed in the accessory carton for installation at the inlet connection of the bronze header.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, setpoint adjustable from 50 to 104 degrees F (maximum can be raised to 107), status and diagnostic messages, PIN control lockout. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and automatic bypass valve built into the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Factory wired for 240 VAC. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 29 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 9 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, ProTek Shield adapter and assembly.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME pool and spa heaters: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak rates the input for elevations up to 2,000 ft and reduces it 4% for each 1,000 ft above sea level beyond that, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eRaypak's pipe sizing table allows 3\/4 in. pipe on the 406A only for the last 5 ft at the gas valve. Size the supply line from the table in the manual.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003cli\u003eOn ASME units a high-limit trip is a manual-reset fault, cleared with the MODE button.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item and is not covered by the warranty. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eTo move the water connections to the other side on an ASME model, Raypak says to call the factory representative for instructions.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061982523611,"sku":"017402","price":5764.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/1am9uC2NAvod7FptqF7lv6IcISgo0hsnT.jpg?v=1791053037"},{"product_id":"pentair-eti-250-natural-gas-pool-and-spa-heater-250-000-btu-titanium-heat-exchanger-461112","title":"Pentair 461112 ETi 250 Natural Gas Pool and Spa Heater, 250,000 BTU, Titanium Heat Exchanger","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e461112\u003c\/strong\u003e: ETi 250 High-Efficiency Pool Heater, 250,000 BTU, natural gas. A pool and spa heater with a Titan-Tough Direct-Fire Titanium heat exchanger and quick heat-up times.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e461112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003eETi 250 High-Efficiency Pool Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBTU\u003c\/th\u003e\n\u003ctd\u003e250,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (in.)\u003c\/th\u003e\n\u003ctd\u003e25L x 25W x 32H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight (lb)\u003c\/th\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e120 or 240\/60Hz\/1Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaker size\u003c\/th\u003e\n\u003ctd\u003e15 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExchanger material\u003c\/th\u003e\n\u003ctd\u003eTitanium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeader material\u003c\/th\u003e\n\u003ctd\u003ePolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePool type\u003c\/th\u003e\n\u003ctd\u003eIn-Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003ctd\u003eResidential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379877491\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDocuments\u003c\/th\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/eti-400-eti-250\/eti-250-user-manuals\/eti250-installation-and-users-guide-english.pdf\"\u003eInstallation and User Guide (PDF)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/eti-400-eti-250\/brochure\/eti-heater-family-brochure-english.pdf\"\u003eETi 400 \u0026amp; ETi 250 Family Brochure (PDF)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/eti-400-eti-250\/eti-250-user-manuals\/heat-exchanger-cleaning-kit\/eti250-coil-cleaning-kit-instructions-english.pdf\"\u003eHeat Exchanger Coil Cleaning Kit Instructions (PDF)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair Heaters and Heat Pumps catalog 2025-2026 p. 94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 96% thermal efficiency*\u003c\/li\u003e\n\u003cli\u003eTitan-Tough Direct-Fire Titanium Heat Exchanger with ASME certified construction, resistant to corrosion\u003c\/li\u003e\n\u003cli\u003eMultiple orientation options for gas line connection and easy-access keypad positioning\u003c\/li\u003e\n\u003cli\u003e250,000 BTU heating power\u003c\/li\u003e\n\u003cli\u003eThree-year parts and labor warranty\u003c\/li\u003e\n\u003cli\u003eA replacement for the MasterTemp High Performance Heater, with the same plumbing alignments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":44061984358619,"sku":"461112","price":7550.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/ETi250-1_grande_a9022879-9b25-4377-9fbb-17d1c48b08cc.webp?v=1752864214"},{"product_id":"raypak-digital-asme-b-r336a-en-c-50-pool-heater-natural-gas-332-500-btu-copper-heat-017373","title":"Raypak 017373 Digital ASME B-R336A-EN-C #50 Pool Heater, Natural Gas, 332,500 BTU, Copper Heat Exchanger, Bronze Headers","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017373\u003c\/strong\u003e: Digital ASME B-R336A-EN-C #50 pool heater, natural gas, 332,500 BTU. A natural gas pool and spa heater with a copper heat exchanger, rated for elevations from 0 to 2000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eUNIT-C\/P B-R336A-EN-C #50 ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891041559\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e332,500 BTU\/h (332.5 MBTUH, 97.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e250 lb (with stackless top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital ASME 336A is the code-stamped version of the Digital atmospheric gas heater. Bronze headers and an ASME-certified copper fin-tube heat exchanger take the place of the polymer headers used on the residential model, for pools and spas where an ASME heater is required, typically commercial sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRelated items\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe propane ASME 336A is a different item number (017385).\u003c\/li\u003e\n\u003cli\u003eRaypak also lists item 017377 with the #51 orifice and item 017381 with the #52 orifice; on copper models Raypak gives #51 for 2,000 to 6,000 ft and #52 for 6,000 to 9,000 ft.\u003c\/li\u003e\n\u003cli\u003eThe cupronickel ASME 336A is a different item number (017401).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater.\u003c\/li\u003e\n\u003cli\u003eIndoor installation needs Raypak indoor stack kit 009840 and a vent to the outside, or the D-2 power vent kit (010745 for 120 V, 009833 for 240 V).\u003c\/li\u003e\n\u003cli\u003ePump flow between 35 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eASME heat exchanger: bronze headers and copper fin tubes, HLW-stamped, 100 PSIG maximum allowable working pressure, registered with the National Board.\u003c\/li\u003e\n\u003cli\u003eA 75 PSI pressure relief valve is included, shipped loose for the 3\/4 in. NPT port in the header.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield sacrificial assembly and its adapter are included, shipped loose for installation at the inlet connection. It protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz, through a dual-voltage transformer; Raypak states the heater is factory-wired for 240 VAC. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. Right-hand as shipped; Raypak lists left-hand as an optional field change.\u003c\/li\u003e\n\u003cli\u003eCabinet 26 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 8 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, and the ProTek Shield adapter with ProTek Shield, O-ring and wing nut.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME models: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak reduces the input rating 4% for each 1,000 ft above sea level beyond 2,000 ft, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eThis is the atmospheric ASME model. Raypak's Low NOx ASME heaters are the separate 207A to 407A models.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061993369819,"sku":"017373","price":4538.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/1fUtkIvP3zi_wlDTWKuwBUOcRXgO7GoYa.jpg?v=1791053036"},{"product_id":"raypak-digital-asme-b-r206a-en-x-50-pool-heater-natural-gas-199-500-btu-cupronickel-bronze-017399","title":"Raypak 017399 Digital ASME B-R206A-EN-X #50 Pool Heater, Natural Gas, 199,500 BTU, Cupronickel, Bronze Headers","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017399\u003c\/strong\u003e: Digital ASME B-R206A-EN-X #50 pool heater, natural gas, 199,500 BTU. A natural gas pool and spa heater with a cupro-nickel heat exchanger, rated 199,500 BTU\/h input for installations from 0 to 2,000 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eB-R206A-EN-X #50, Cupro-Nickel Heat Exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891042167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e199,500 BTU\/h (58.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCupro-Nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e212 lb with stackless top; indoor draft hood 14 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital ASME 206A is the commercial version of the Raypak Digital atmospheric gas heater. Its heat exchanger is ASME-certified and National Board registered, with bronze headers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCommercial pools and spas, and other installations where an ASME-certified heater is required.\u003c\/li\u003e\n\u003cli\u003eRaypak lists the propane version as item 017411, item 017403 for 2,000 to 6,000 ft and item 017407 for 6,000 to 9,000 ft. The same heater with copper tubes is Raypak item 017371.\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009838 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 20 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eThis is an atmospheric heater, not a Low NOx model. Raypak's Low NOx ASME heaters are the 207A to 407A series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eASME heat exchanger, HLW-stamped and National Board registered, 100 PSIG maximum allowable working pressure. Bronze headers, cupronickel fin tubes, steel tube sheets.\u003c\/li\u003e\n\u003cli\u003e75 PSI pressure relief valve included, shipped loose in the accessory carton. The header has a 3\/4 in. NPT connection for it.\u003c\/li\u003e\n\u003cli\u003eProTek Shield sacrificial assembly with its adapter, packed in the accessory carton for installation at the inlet connection of the bronze header.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, setpoint adjustable from 50 to 104 degrees F (maximum can be raised to 107), status and diagnostic messages, PIN control lockout. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and automatic bypass valve built into the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Factory wired for 240 VAC. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 20 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 6 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, ProTek Shield adapter and assembly.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME pool and spa heaters: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak rates the input for elevations up to 2,000 ft and reduces it 4% for each 1,000 ft above sea level beyond that, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003cli\u003eOn ASME units a high-limit trip is a manual-reset fault, cleared with the MODE button.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item and is not covered by the warranty. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eTo move the water connections to the other side on an ASME model, Raypak says to call the factory representative for instructions.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44061996253403,"sku":"017399","price":4290.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/41wDg_p9suL._AC___83063.jpg?v=1766500688"},{"product_id":"raypak-digital-p-r266a-en-c-50-pool-heater-natural-gas-266-000-btu-copper-heat-exchanger-0-009217","title":"Raypak 009217 Digital P-R266A-EN-C #50 Pool Heater, Natural Gas, 266,000 BTU, Copper Heat Exchanger, 0-2000 ft, Electronic Ignition, Rheem 009963","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e009217\u003c\/strong\u003e: Digital P-R266A-EN-C #50 pool heater, natural gas, 266,000 BTU. A Digital natural gas pool and spa heater with polymer headers, copper tubing and electronic ignition, for installations from 0 to 2000 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e009217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eP-R266A-EN-C #50, Digital with Polymer Headers, Copper Tubing, Electronic Ignition, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891012764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e266,000 BTU\/h (77.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e210 lb with stackless top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 13, 93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDigital control\u003c\/li\u003e\n\u003cli\u003ePolymer headers\u003c\/li\u003e\n\u003cli\u003eCopper tubing\u003c\/li\u003e\n\u003cli\u003eElectronic ignition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital 266A is an atmospheric gas heater for pools and spas. Its digital thermostat shows water temperature and status messages on an LCD.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNatural gas only. The propane 266A for the same elevation is a different item number (009225).\u003c\/li\u003e\n\u003cli\u003eRaypak lists item 009221 for 2,000 to 6,000 ft and item 009847 for 6,000 to 9,000 ft.\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009839 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 25 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield sacrificial assembly under the inlet connection protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 23 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 7 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: two years parts and labor, or one year when installed anywhere other than a single-family home.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 009963, model P-M266A-EN-C #50, is the same heater sold under the Rheem label.\u003c\/li\u003e\n\u003cli\u003eRuud cross-reference: Ruud item 009995, model P-D266A-EN-C #50, is the same heater sold under the Ruud label.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak's rated input applies up to 2,000 ft. Above that the manual reduces input 4% for each 1,000 ft above sea level.\u003c\/li\u003e\n\u003cli\u003eThis is an atmospheric heater, not a Low NOx model. Raypak's Low NOx Digital heaters are the 207A to 407A models, and Raypak notes that some states and localities require Low NOx heaters.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062008279259,"sku":"009217","price":3374.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/8074-a-2022_1.jpg?v=1713996229"},{"product_id":"raypak-natural-gas-iid-combination-valve-for-206a-266-266a-336a-399-406a-408a-rp2100-r185-003900f","title":"Raypak 003900F Natural Gas IID Combination Valve for 206A, 266\/266A, 336A, 399\/406A, 408A, RP2100 R185-R405 Pool Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e003900F\u003c\/strong\u003e: Combination Gas Valve, Natural Gas, IID.\u003c\/p\u003e\n\u003cp\u003eThe natural gas combination valve Raypak lists for its electronic ignition (IID) pool heaters, including the 206A to 406A, 408A and RP2100 series.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e003900F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eCombination Valve - Nat. IID (KIT-GAS VALVE IID NAT POOL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits Raypak models\u003c\/th\u003e\n\u003ctd\u003e206A, 266\/266A, 336A, 399\/406A; 408A; RP2100 185A, 265A, 335A, 405A; RP2100 185B, 265B, 335B, 405B; also listed for 53A, 53B, 055A, 055B, 105A, 105B, 151, 153 IID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplaces\u003c\/th\u003e\n\u003ctd\u003e600972 (VALVE-COMBO GAS SLOW 3\/4 NAT); 600973 (VALVE-COMBO GAS SLOW 3\/4 NAT); 005242F (KIT-GAS VALVE IID NAT POOL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e662766386950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 21, 43; Raypak IPL 9100.56 Millivolt 206A-406A p. 5; Raypak IPL 241452 Pro Series 268A, 408A p. 42; Raypak IPL 9100.554 RP2100 R185A-R405A p. 4; Raypak IPL 9100.555 RP2100 R185B-R405B p. 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis valve sits on the burner tray and feeds gas to the pilot and the main burners. It is powered by the heater's 24 VAC control circuit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProduction dates and older models:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e206A to 406A built from October 2004\u003c\/li\u003e\n\u003cli\u003eRP2100 R185A to R405A built November 1998 to October 2003; R185B to R405B built October 2003 to October 2004; R185 to R405 built November 1993 to October 1998\u003c\/li\u003e\n\u003cli\u003eVersa 185A to 405A (1986 to 1988), 185B to 405B (1988 to 1992), 185C to 405C (1992 to 1993)\u003c\/li\u003e\n\u003cli\u003eVersa 055A (1987 to 1989), 055B (1990 to 2013), 105A (1991 to 1999), 105B (1999 to 2006), 155B\/C (1991 to 2006)\u003c\/li\u003e\n\u003cli\u003eSpa-Pak 053A and 053B (1984 to 1987), Gemini and Spa-Pak 153A (1984 to 1987), 151 with electronic ignition (1980 to 1981)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNot for:\u003c\/strong\u003e propane heaters (use Raypak 004306F), millivolt natural gas heaters (use Raypak 003898F), Low NOx 207A to 407A (use Raypak 010329F), or the 106A and 156A (use Raypak 014867F).\u003c\/p\u003e\u003cp\u003eThe 206A to 406A manual gives about 4.0 in. WC as the regulated pressure at the gas valve on natural gas, measured with a manometer. Changing a heater from one fuel to the other takes more than a valve; Raypak lists separate conversion kits and requires a qualified agency to do the work. Replacing a gas valve is a job for a qualified gas technician.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062012047579,"sku":"003900F","price":275.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/003900F.jpg?v=1731975816"},{"product_id":"raypak-digital-asme-b-r336a-en-x-50-pool-heater-natural-gas-332-500-btu-cupronickel-bronze-017401","title":"Raypak 017401 Digital ASME B-R336A-EN-X #50 Pool Heater, Natural Gas, 332,500 BTU, Cupronickel, Bronze Headers","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017401\u003c\/strong\u003e: Digital ASME B-R336A-EN-X #50 pool heater, natural gas, 332,500 BTU, cupronickel. A natural gas pool and spa heater with a cupronickel heat exchanger, built for elevations from 0 to 2,000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eB-R336A-EN-X #50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891042181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e332.5 MBTUH (332,500 BTU\/h; 97.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCupro-Nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e250 lb with stackless top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital ASME 336A is built for commercial pools and spas and other installations where an ASME-certified heater is required. The heat exchanger is ASME-certified, HLW-stamped and National Board registered, 100 PSIG maximum allowable working pressure, with bronze headers, cupronickel fin tubes and steel tube sheets. Raypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOther versions:\u003c\/strong\u003e propane is Raypak item 017413; 2,000 to 6,000 ft is item 017405 and 6,000 to 9,000 ft is item 017409; the same heater with copper tubes is item 017373.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009840 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 35 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eThis is an atmospheric heater, not a Low NOx model. Raypak's Low NOx ASME heaters are the 207A to 407A series.\u003c\/li\u003e\n\u003cli\u003e75 PSI pressure relief valve included, shipped loose in the accessory carton; the header has a 3\/4 in. NPT connection for it.\u003c\/li\u003e\n\u003cli\u003eProTek Shield sacrificial assembly with its adapter, packed in the accessory carton for installation at the inlet connection of the bronze header.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, setpoint adjustable from 50 to 104 degrees F (maximum can be raised to 107), status and diagnostic messages, PIN control lockout. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and automatic bypass valve built into the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Factory wired for 240 VAC. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 26 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 8 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, ProTek Shield adapter and assembly.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME pool and spa heaters: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak rates the input for elevations up to 2,000 ft and reduces it 4% for each 1,000 ft above sea level beyond that, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003cli\u003eOn ASME units a high-limit trip is a manual-reset fault, cleared with the MODE button.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item and is not covered by the warranty. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eTo move the water connections to the other side on an ASME model, Raypak says to call the factory representative for instructions.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062015979739,"sku":"017401","price":5152.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/1AZIhyN6hurJ4QYkj7l2LeldghP5CPOwL.jpg?v=1791053036"},{"product_id":"raypak-digital-p-r206a-en-c-50-pool-and-spa-heater-natural-gas-199-500-btu-copper-heat-009216","title":"Raypak 009216 Digital P-R206A-EN-C #50 Pool \u0026 Spa Heater, Natural Gas, 199,500 BTU, Copper Heat Exchanger, Electronic Ignition, 0-2000 ft","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e009216\u003c\/strong\u003e: Digital P-R206A-EN-C #50 pool and spa heater, natural gas, 0-2000 ft.\u003c\/p\u003e\n\u003cp\u003eA natural gas pool and spa heater with a copper heat exchanger and 199,500 BTU\/h input, built for installations from 0 to 2,000 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e009216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eP-R206A-EN-C #50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891012757\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e199.5 MBTUH (199,500 BTU\/h, 58.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e187 lb (with stackless top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe 206A is the smallest heater in Raypak's Digital gas series. It has a microprocessor thermostat with a digital display, electronic ignition that lights the pilot and burners on each call for heat, and a copper fin-tube heat exchanger with polymer headers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak builds separate versions for 2,000 to 6,000 ft (009220) and 6,000 to 9,000 ft (009846).\u003c\/li\u003e\n\u003cli\u003eResidential pools and spas, with 20 to 100 GPM of flow through the heater.\u003c\/li\u003e\n\u003cli\u003eOutdoor installation with the stackless top that ships with the heater.\u003c\/li\u003e\n\u003cli\u003eIndoor installation with Raypak's indoor stack kit 009838 (6 in. drafthood) and a Category I vent.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital series at 82% efficiency.\u003c\/li\u003e\n\u003cli\u003eSupply pressure 6 in. WC minimum, 10.5 in. WC maximum.\u003c\/li\u003e\n\u003cli\u003eBurner: atmospheric. This is not a Low NOx model; Raypak's Low NOx Digital heaters are the ASME models 207A to 407A.\u003c\/li\u003e\n\u003cli\u003eIgnition: electronic intermittent ignition.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield module under the inlet connection protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eWater connections: 2 in. slip. Two 2 in. CPVC union halves with O-rings are included.\u003c\/li\u003e\n\u003cli\u003eGas connection: 3\/4 in. NPT. Flue: 6 in.\u003c\/li\u003e\n\u003cli\u003ePower: wired for 240 V at the factory, convertible to 120 V, single phase, 60 Hz. Draws 2 A at 240 V or 4 A at 120 V. Not for 208 V.\u003c\/li\u003e\n\u003cli\u003eControl: digital thermostat with pool and spa modes; accepts a two-wire or three-wire remote.\u003c\/li\u003e\n\u003cli\u003eCabinet width 20 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor top, two 2 in. CPVC union halves with O-rings, a finish flange for the gas line and a bonding lug.\u003c\/li\u003e\n\u003cli\u003eCertified to ANSI Z21.56 \/ CSA 4.7 for indoor or outdoor use with the correct top.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: 2 years parts and labor when installed by a licensed installer at a single-family home; 1 year in any other setting.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 009962, model P-M206A-EN-C #50, is the same heater sold under the Rheem label.\u003c\/li\u003e\n\u003cli\u003eRuud cross-reference: Ruud item 009994, model P-D206A-EN-C #50, is the same heater sold under the Ruud label.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAbove 2,000 ft Raypak calls for cutting the input 4% per 1,000 ft, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eOptional Raypak kits for the 206A: outdoor stack 009834, indoor stack 009838, D-2 power vent 010744 (120 V) or 009832 (240 V).\u003c\/li\u003e\n\u003cli\u003eRaypak requires a sediment trap on the gas line, and the heater should sit at least 3 ft from a heat pump or outdoor condensing unit.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear part. Raypak says to replace it once it is down to about 40% of its original weight.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer and meet local codes.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062017028315,"sku":"009216","price":3023.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/Snipaste_2024-05-09_09-57-07.jpg?v=1715266638"},{"product_id":"raypak-natural-gas-iid-low-nox-pilot-kit-for-207a-266l-267a-337a-399l-407a-pool-heaters-010232f","title":"Raypak 010232F Natural Gas IID Low NOx Pilot Kit for 207A, 266L\/267A, 337A, 399L\/407A Pool Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e010232F\u003c\/strong\u003e: Natural Gas IID Low NOx Pilot Kit. A replacement natural gas pilot for Raypak 207A, 266L\/267A, 337A and 399L\/407A Low NOx pool heaters with intermittent ignition (IID).\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e010232F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003ePilot Nat. IID Low NOx (KIT-PILOT 207-407)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits Raypak models\u003c\/th\u003e\n\u003ctd\u003e207A, 266L\/267A, 337A, 399L\/407A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplaces\u003c\/th\u003e\n\u003ctd\u003e011928F (KIT-IGNITER PILOT 207-407)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e662766683820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 36; Raypak IPL 241793 Digital 207A-407A p. 45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese heaters light the pilot by spark on each call for heat and open the main gas valve only once the pilot flame is proven, so a restricted or dirty pilot shows up as a weak flame signal or an ignition fault. Raypak's model history dates the residential models 2004 to 2023.\u003c\/p\u003e\u003cp\u003eNot for atmospheric 206A, 266A, 336A or 406A heaters, which use pilot 002003F.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe parts list gives no separate part number for the pilot electrode (shown as N\/A).\u003c\/li\u003e\n\u003cli\u003eListed separately: pilot mounting bracket (010233F for 207A, 010234F for 267A, 010235F for 337A, 010236F for 407A), pilot tube 011926F, high tension wire 010349F and metric adapter nut 011927F.\u003c\/li\u003e\n\u003cli\u003eThe Lo NOx pilot drawing in Raypak's manual (Figure 57, electrode alignment detail) gives a dimension of 0.18 in. plus or minus 0.04 in. (4.57 mm plus or minus 1 mm).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003ePilot and gas work is for a qualified technician.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062017323227,"sku":"010232F","price":131.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/Raypak_PILOT_207-407-KIT.jpg?v=1721313247"},{"product_id":"raypak-014784-above-ground-156a-pool-spa-heater-natural-gas-150000-btu","title":"Raypak 014784 Above Ground Digital P-R156A-EN-C Pool \u0026 Spa Heater, Natural Gas, 0-4999 ft, Copper, Polymer Headers (Rheem 014802)","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e014784\u003c\/strong\u003e: Above Ground Digital P-R156A-EN-C pool and spa heater, natural gas, 0-4999 ft.\u003c\/p\u003e\n\u003cp\u003eA gas-fired heater with polymer headers, digital control and electronic ignition for heating residential pools and spas.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e014784\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eP-R156A-EN-C: Polymer Headers, Digital Control, Electronic Ignition, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891035794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-4999 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper, polymer headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e100 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 61, 93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak 156A is the digital model in the Above Ground series, an atmospheric gas heater for above-ground pools and spas. A touchpad and LCD set the pool and spa temperatures and report status and faults in plain words, and the heater accepts a two-wire or three-wire remote.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe propane 156A is item 014786; item 014785 is the 5,000 to 9,999 ft natural gas version.\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top. Indoor installation needs Raypak drafthood kit 014358 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 20 and 70 GPM. Above 70 GPM Raypak requires an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eRaypak states the Above Ground series cannot be sold in Low NOx markets, including Southern California and Utah.\u003c\/li\u003e\n\u003cli\u003eRaypak lists the Above Ground series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure at the heater: 5 in. WC minimum with the heater running, 10.5 in. WC maximum. Gas connection 1\/2 in. NPT.\u003c\/li\u003e\n\u003cli\u003eDigital control with POOL and SPA modes and a power switch. Setpoint range 65 F to 104 F as shipped. A service menu shows pilot flame strength, supply voltage, run time, cycle count and the last ten faults. Remote-ready through the supplied 7-pin connector.\u003c\/li\u003e\n\u003cli\u003eSpark-to-pilot electronic ignition; the main gas valve opens only after the pilot flame is proven.\u003c\/li\u003e\n\u003cli\u003eStainless steel tube sheets with a built-in automatic bypass valve.\u003c\/li\u003e\n\u003cli\u003eShips with a 120 VAC three-prong cord; the transformer can be rewired for 240 VAC. Draws 4 A at 120 V or 2 A at 240 V. Raypak requires a grounded, GFCI-protected supply.\u003c\/li\u003e\n\u003cli\u003eWater connections: two 2 in. CPVC unions, supplied. PVC pipe can be glued directly into them.\u003c\/li\u003e\n\u003cli\u003eCabinet depth 27 in. Flue diameter 6 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: two 2 in. CPVC unions with O-rings, plastic finish flange for the gas line, bonding lug and the manual. The outdoor stackless top is standard.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: two years parts and labor, or one year when installed anywhere other than a single-family home. The warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 014802, model P-M156A-EN-C. Ruud cross-reference: Ruud item 014820, model P-D156A-EN-C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e The heater must sit at least 5 ft from the inside wall of the pool unless a solid fence, wall or other permanent barrier separates them. It can be installed on combustible flooring, but not on carpet. For sites with frequent high wind Raypak offers an optional outdoor stack, part 014719. Raypak reduces the input 4% for each 1,000 ft above sea level when installed above 2,000 ft; for such sites Raypak says to consult the factory. Converting to propane takes Raypak kit 014915F and must be done by a qualified agency. Gas, venting and electrical work must be done by a qualified installer and meet local codes.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062017487067,"sku":"014784","price":2649.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/61PzOw2eCzL.jpg?v=1721585336"},{"product_id":"raypak-avia-p-r264a-en-c-pool-heater-natural-gas-264-000-btu-copper-heat-exchanger-018032","title":"Raypak 018032 Avia P-R264A-EN-C Pool Heater, Natural Gas, 264,000 BTU, Copper Heat Exchanger","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e018032\u003c\/strong\u003e: Avia P-R264A-EN-C pool heater, natural gas, 264,000 BTU, copper heat exchanger. A Low NOx Avia gas pool heater with polymer headers and copper tubing, rated at 264,000 BTU\/h input on natural gas.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e018032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eP-R264A-EN-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eLow NOx AVIA Pool Heater with Polymer Headers, Copper Tubing, Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891047278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e264,000 BTU\/h (77.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-10,000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e155 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 1, 93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eWi-Fi is built into the control, so the heater can be set and watched from the Raymote phone app with no separate control panel. Rated at 84% thermal efficiency with a straight-tube heat exchanger.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNatural gas installations (certified to 4,500 ft; above that a qualified technician adjusts the gas valve)\u003c\/li\u003e\n\u003cli\u003eResidential pools and spas on 2 in. plumbing, with 40 to 100 GPM of flow through the heater\u003c\/li\u003e\n\u003cli\u003eOutdoor pads using the vent cap supplied with the heater, or indoor and direct-vent installations with the venting Raypak specifies in the manual\u003c\/li\u003e\n\u003cli\u003eReplacing an older heater: water and gas connections line up with common heaters, and the cabinet is about 23 in. square (a 2x2 footprint)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSupply pressure 3.5 in. WC minimum while firing, 10.5 in. WC maximum static\u003c\/li\u003e\n\u003cli\u003eStainless steel combustion chamber\u003c\/li\u003e\n\u003cli\u003eWater connections: 2 in. Two 2 in. CPVC tailpieces with ring nuts and O-rings come in the carton\u003c\/li\u003e\n\u003cli\u003eGas connection: 3\/4 in. NPT. Flue: 4 in.\u003c\/li\u003e\n\u003cli\u003ePower: 240 V as shipped, convertible to 120 V, single phase, 60 Hz. Draws about 1.2 A at 240 V or 1.6 A at 120 V. Not for 208 V\u003c\/li\u003e\n\u003cli\u003eControl: touchpad with LCD display, pool and spa modes, and Wi-Fi for the Raymote app. A 3-wire remote harness is included for automation systems, and the control can run a Raypak Protege or AquaStar Smart variable-speed pump\u003c\/li\u003e\n\u003cli\u003eProTek Shield module on the water inlet protects the heat exchanger from galvanic corrosion (replacement module 017960F)\u003c\/li\u003e\n\u003cli\u003eCabinet: 23.24 in. wide x 23.22 in. deep x 30.38 in. high, not counting the outdoor vent cover and the water header. Weight 135 lb\u003c\/li\u003e\n\u003cli\u003eAlso in the carton: 120 V blower adapter, auxiliary harness and Raymote quick start guide\u003c\/li\u003e\n\u003cli\u003eCertified to ANSI Z21.56 \/ CSA 4.7, SCAQMD Rule 1146.2 and SJVAPCD Rule 4308\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: 3 years parts and labor when installed by a licensed installer at a single-family home; 1 year in any other setting\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 018068, model P-M264A-EN-C. Ruud cross-reference: Ruud item 018092, model P-D264A-EN-C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe ProTek Shield is a wear part; Raypak says to replace it once it is down to about 40% of its original weight\u003c\/li\u003e\n\u003cli\u003eRaypak requires a sediment trap on the gas line\u003c\/li\u003e\n\u003cli\u003eChlorinators and chemical feeders go downstream of the heater, with a check valve between them\u003c\/li\u003e\n\u003cli\u003eKeep the heater at least 3 ft from a heat pump or outdoor condensing unit\u003c\/li\u003e\n\u003cli\u003eConnecting to Raymote needs a reliable Wi-Fi signal at the equipment pad\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer and meet local codes\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44062025646299,"sku":"018032","price":3493.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/184761_0_20211228145951.jpg?v=1721586583"},{"product_id":"pentair-mastertemp-250-natural-gas-pool-and-spa-heater-250-000-btu-low-nox-copper-exchanger-460732","title":"Pentair 460732 MasterTemp 250 Natural Gas Pool and Spa Heater, 250,000 BTU, Low NOx, Copper Exchanger","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e460732\u003c\/strong\u003e: MasterTemp 250 Natural Gas Pool and Spa Heater, 250,000 BTU. The MasterTemp High-Performance Heater offers smart features and an optional energy-saving Smart Bypass Valve Kit.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e460732\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003eHTR 250 MASTERTEMP NA (per Pentair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBTU\u003c\/th\u003e\n\u003ctd\u003e250,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger efficiency\u003c\/th\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExchanger material\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeader material\u003c\/th\u003e\n\u003ctd\u003ePolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarton weight\u003c\/th\u003e\n\u003ctd\u003e133 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003eCertified for low NOx emissions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379724443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDocuments\u003c\/th\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/mastertemp-heater-manual-english.pdf\"\u003eInstallation and User's Guide, English (PDF)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair Heaters and Heat Pumps catalog 2025-2026 p. 96; Pentair Heaters and Heat Pumps catalog 2021 p. 106; Pentair Heaters and Heat Pumps catalog 2020 p. 104; Pentair Heaters and Heat Pumps catalog 2019 p. 102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmart connectivity via the Pentair Automation Systems enables you to manage pool functions anytime, anywhere.\u003c\/li\u003e\n\u003cli\u003eFull-text digital display combines new functions and a user-friendly menu for easy operation and diagnostics.\u003c\/li\u003e\n\u003cli\u003eDigital connectivity with your pool's automation system and an advanced ignition control module with flame strength sensor help to ensure optimal heater performance.\u003c\/li\u003e\n\u003cli\u003eAlerts pushed to a smart device to keep you updated on heater performance and real-time status.\u003c\/li\u003e\n\u003cli\u003eOptional Smart Heater Bypass valve control diverts water flow when the heater isn't needed to help save up to 35% in yearly operational costs.*\u003c\/li\u003e\n\u003cli\u003eAvailable only in store from Pentair dealers or retail stores\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":44164455530715,"sku":"460732","price":3200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/MasterTemp-banner.png.thumb.1280.1280.png?v=1721579168"},{"product_id":"pentair-mastertemp-400-natural-gas-pool-and-spa-heater-400-000-btu-low-nox-copper-exchanger-460736","title":"Pentair 460736 MasterTemp 400 Natural Gas Pool and Spa Heater, 400,000 BTU, Low NOx, Copper Exchanger","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e460736\u003c\/strong\u003e: MasterTemp 400 High Performance Pool and Spa Heater, Natural Gas, 400,000 BTU.\u003c\/p\u003e\n\u003cp\u003eA natural gas pool and spa heater with a full-text digital display and connectivity to Pentair automation systems.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e460736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Pentair)\u003c\/th\u003e\n\u003ctd\u003eMasterTemp 400, Natural (HTR 400 MASTERTEMP NA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBTU\u003c\/th\u003e\n\u003ctd\u003e400,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeader material\u003c\/th\u003e\n\u003ctd\u003ePolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003eCertified for low NOx emissions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation\u003c\/th\u003e\n\u003ctd\u003eCertified for outdoor and indoor installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePool type\u003c\/th\u003e\n\u003ctd\u003eIn-Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003eResidential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir intake kit\u003c\/th\u003e\n\u003ctd\u003eOrder part number 461031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarton quantity\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarton weight\u003c\/th\u003e\n\u003ctd\u003e136 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e160 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage dimensions\u003c\/th\u003e\n\u003ctd\u003e36 x 25 x 30 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379724078\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDocuments\u003c\/th\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/mastertemp-heater-manual-english.pdf\"\u003eInstallation and User's Guide (PDF)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/archive\/mastertemp400-pool-and-spa-heater-installation-and-users-guide-french.pdf\"\u003eInstallation and User's Guide, French (PDF)\u003c\/a\u003e, \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp1\/mastertemp-max-e-therm-heater-direct-air-intake-duct-3-inch-pvc-pipe-kit-installation-instructions.pdf\"\u003eDirect Air Intake Duct Kit Instructions (PDF)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair Heaters and Heat Pumps catalog 2025-2026 p. 96; Pentair Heaters and Heat Pumps catalog 2021 p. 106; Pentair Heaters and Heat Pumps catalog 2020 p. 104; Pentair Heaters and Heat Pumps catalog 2019 p. 102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmart connectivity via Pentair automation systems lets you manage pool functions anytime, anywhere.\u003c\/li\u003e\n\u003cli\u003eFull-text digital display combines new functions and a user-friendly menu for easy operation and diagnostics.\u003c\/li\u003e\n\u003cli\u003eDigital connectivity with your pool's automation system and an advanced ignition control module with flame strength sensor help ensure optimal heater performance.\u003c\/li\u003e\n\u003cli\u003eAlerts pushed to a smart device keep you updated on heater performance and real-time status.\u003c\/li\u003e\n\u003cli\u003eOptional Smart Heater Bypass valve control diverts water flow when the heater is not needed, which Pentair says can help save up to 35% in yearly operational costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eUses a hot surface electronic ignition and a rotating digital display. Water connections are 2-inch PVC unions. Listed dimensions: 32.6 in. L x 23 in. W x 28 in. H. Pentair describes the MasterTemp's compact design and quiet operation.\u003c\/p\u003e\u003cp\u003eCan replace Pentair MasterTemp and Sta-Rite Max-E-Therm heaters of similar BTU rating.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e2-inch union connections\u003c\/li\u003e\n\u003cli\u003eOwner's manual with installation and operation instructions\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAlways have this heater installed by a licensed professional. Regular maintenance is recommended.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":44167058817243,"sku":"460736","price":4050.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/2637-a-sq-2017__16262.jpg?v=1744032873"},{"product_id":"raypak-digital-asme-b-r266a-en-x-50-pool-heater-natural-gas-266-000-btu-cupronickel-bronze-017400","title":"Raypak 017400 Digital ASME B-R266A-EN-X #50 Pool Heater, Natural Gas, 266,000 BTU, Cupronickel, Bronze Headers","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017400\u003c\/strong\u003e: Digital ASME B-R266A-EN-X #50 pool heater, natural gas, 266,000 BTU. A natural gas pool and spa heater with a cupronickel heat exchanger, built for installations from 0 to 2000 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eB-R266A-EN-X #50, Cupro-Nickel Heat Exchanger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891042174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e266,000 BTU\/h (77.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCupro-Nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e235 lb (with stackless top)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital ASME 266A is a natural gas heater for commercial pools and spas and other installations where an ASME-certified heater is required. It pairs the Digital series control and electronic ignition with an ASME-certified, National Board registered heat exchanger with bronze headers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRelated Raypak items:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePropane version: item 017412.\u003c\/li\u003e\n\u003cli\u003e2,000 to 6,000 ft: item 017404. 6,000 to 9,000 ft: item 017408.\u003c\/li\u003e\n\u003cli\u003eSame heater with copper tubes: item 017372.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009839 and a vent to the outside.\u003c\/li\u003e\n\u003cli\u003ePump flow between 25 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eThis is an atmospheric heater, not a Low NOx model. Raypak's Low NOx ASME heaters are the 207A to 407A series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eASME heat exchanger, HLW-stamped and National Board registered, 100 PSIG maximum allowable working pressure. Bronze headers, cupronickel fin tubes, steel tube sheets.\u003c\/li\u003e\n\u003cli\u003e75 PSI pressure relief valve included, shipped loose in the accessory carton. The header has a 3\/4 in. NPT connection for it.\u003c\/li\u003e\n\u003cli\u003eProTek Shield sacrificial assembly with its adapter, packed in the accessory carton for installation at the inlet connection of the bronze header.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, setpoint adjustable from 50 to 104 degrees F (maximum can be raised to 107), status and diagnostic messages, PIN control lockout. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and automatic bypass valve built into the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz. Draws 4 A at 120 V or 2 A at 240 V. Factory wired for 240 VAC. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 23 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 7 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, ProTek Shield adapter and assembly.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME pool and spa heaters: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak reduces the input rating 4% for each 1,000 ft above sea level beyond 2,000 ft, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003cli\u003eOn ASME units a high-limit trip is a manual-reset fault, cleared with the MODE button.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item and is not covered by the warranty. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eTo move the water connections to the other side on an ASME model, Raypak says to call the factory representative for instructions.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44177642193115,"sku":"017400","price":4661.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/1FJgDiGY1uDYmnmwMWS0JQQy1rKhnxnpG.jpg?v=1791053036"},{"product_id":"raypak-ignition-control-natural-gas-iid-for-106a-analog-rp2100-r185a-r405a-1993-2003-and-004817b","title":"Raypak 004817B Ignition Control, Natural Gas IID, for 106A Analog, RP2100 R185A-R405A (1993-2003) and Versa Pool Heaters","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e004817B\u003c\/strong\u003e: Ignition Control, Natural Gas (Analog) \/ IID. A replacement ignition control in the control box of Raypak 106A analog and RP2100 R185A-R405A natural gas pool heaters.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e004817B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eIgnition Control Natural Gas (Analog); Ignition Control IID Nat.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFits Raypak models\u003c\/th\u003e\n\u003ctd\u003e106A (156A: N\/A); RP2100 185A, 265A, 335A, 405A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e662766387094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 66; Raypak IPL 9100.554 RP2100 R185A-R405A p. 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eSend us your model and serial number and we will confirm fit before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eRaypak's parts library names this control Kit-Elec Ign W\/O Lock. The W\/Lock control, 004818B, is the one the parts lists give for propane units and for RP2100 Low NOx units.\u003c\/p\u003e\u003cp\u003eAlso listed for: RP2100 R185, R265, R335 and R405 (built 11\/1993 to 10\/1998); Versa 185A to 405A (11\/1986 to 10\/1988) and 185B to 405B and 185C to 405C (10\/1988 to 11\/1993); Versa 155B\/C, 105A and 105B; Versa 055A and 055B; Spa-Pak 053A and 053B, model 151 and model 153A.\u003c\/p\u003e\u003cp\u003eGas ignition parts should be fitted and tested by a qualified service technician.\u003c\/p\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":44199030915291,"sku":"004817B","price":185.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/004817B-2.jpg?v=1721585715"},{"product_id":"raypak-digital-p-r266a-en-x-51-pool-heater-natural-gas-240-000-btu-cupronickel-014939","title":"Raypak 014939 Digital P-R266A-EN-X #51 Pool Heater, Natural Gas, 240,000 BTU, Cupronickel","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e014939\u003c\/strong\u003e: Digital P-R266A-EN-X #51 Pool Heater, Natural Gas, 240,000 BTU, Cupro-Nickel. A natural gas pool and spa heater with a cupro-nickel heat exchanger, rated at 240,000 BTU\/h input for installations from 0 to 2,000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e014939\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eP-R266A-EN-X #51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891032381\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e240,000 BTU\/h (70.3 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCupro-Nickel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThis is the Raypak Digital 266A with a cupronickel fin-tube heat exchanger in place of the standard copper one. The propane cupronickel 266A is a different item number (014951). The copper 266A (item 009217) is rated at 266,000 BTU\/hr. Raypak lists other versions of this model with different burner orifices, so ask before ordering for an installation above 2,000 ft.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009839 and a vent to the outside, or the D-2 power vent kit (010744 for 120 V, 009832 for 240 V).\u003c\/li\u003e\n\u003cli\u003ePump flow between 25 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eRaypak lists the Digital series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003ePolymer headers. A ProTek Shield sacrificial assembly under the inlet connection protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz, through a dual-voltage transformer; factory-wired for 240 VAC. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. PVC pipe can be glued directly to the unions.\u003c\/li\u003e\n\u003cli\u003eCabinet 23 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 7 in. Shipping weight 210 lb with the stackless top.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty: two years parts and labor, or one year when installed anywhere other than a single-family home.\u003c\/li\u003e\n\u003cli\u003eRheem cross-reference: Rheem item 014967, model P-M266A-EN-X #51. Ruud cross-reference: Ruud item 014995, model P-D266A-EN-X #51.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReplacement heat exchangers and tube bundles for this heater must be the cupronickel versions; Raypak states copper and cupronickel parts are not interchangeable.\u003c\/li\u003e\n\u003cli\u003eRaypak reduces the input 4% for each 1,000 ft above sea level beyond 2,000 ft, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item; replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":48314583056603,"sku":"014939","price":3742.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/YzlYiwAg__60242__91685.png?v=1775762174"},{"product_id":"raypak-017372-digital-asme-266a-pool-heater-natural-gas-266000-btu","title":"Raypak 017372 Digital ASME B-R266A-EN-C #50 Pool Heater, Natural Gas, 266,000 BTU, Copper Heat Exchanger","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017372\u003c\/strong\u003e: Digital ASME B-R266A-EN-C #50 pool heater, natural gas, 266,000 BTU, copper heat exchanger.\u003c\/p\u003e\n\u003cp\u003eA natural gas pool and spa heater with a copper heat exchanger and 266,000 BTU\/h input, built for 0 to 2000 ft elevation.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eUNIT-C\/P B-R266A-EN-C #50 ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891041542\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e266,000 BTU\/h (77.9 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e235 lb with stackless top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital ASME 266A is the code-stamped version of the Digital atmospheric gas heater. Bronze headers and an ASME-certified copper fin-tube heat exchanger take the place of the polymer headers used on the residential model, for pools and spas where an ASME heater is required, typically commercial sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMade for\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNatural gas only. The propane ASME 266A is a different item number (017384).\u003c\/li\u003e\n\u003cli\u003eBurner orifice #50. Raypak also lists item 017376 with the #51 orifice and item 017380 with the #52 orifice; on copper models Raypak gives #51 for 2,000 to 6,000 ft and #52 for 6,000 to 9,000 ft.\u003c\/li\u003e\n\u003cli\u003eThe cupronickel ASME 266A is a different item number (017400).\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009839 and a vent to the outside, or the D-2 power vent kit (010744 for 120 V, 009832 for 240 V).\u003c\/li\u003e\n\u003cli\u003ePump flow between 25 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eASME heat exchanger: bronze headers and copper fin tubes, HLW-stamped, 100 PSIG maximum allowable working pressure, registered with the National Board.\u003c\/li\u003e\n\u003cli\u003eA 75 PSI pressure relief valve is included, shipped loose for the 3\/4 in. NPT port in the header.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield sacrificial assembly and its adapter are included, shipped loose for installation at the inlet connection. It protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz, through a dual-voltage transformer; Raypak states the heater is factory-wired for 240 VAC. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. Right-hand as shipped; Raypak lists left-hand as an optional field change.\u003c\/li\u003e\n\u003cli\u003eCabinet 23 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 7 in.\u003c\/li\u003e\n\u003cli\u003eThe current manual gives a shipping weight of 229 lb with the stackless top.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, and the ProTek Shield adapter with ProTek Shield, O-ring and wing nut.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME models: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak rates the input for elevations up to 2,000 ft and reduces it 4% for each 1,000 ft above sea level beyond that, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eThis is the atmospheric ASME model. Raypak's Low NOx ASME heaters are the separate 207A to 407A models.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":48802050080987,"sku":"017372","price":4048.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/raypak_digital_ASME_600x600_a6a5410c-830b-4bac-bf5b-5568f2866973.png?v=1788443714"},{"product_id":"pentair-mastertemp-200-natural-gas-pool-and-spa-heater-200-000-btu-460730","title":"Pentair 460730 MasterTemp 200 Natural Gas Pool and Spa Heater, 200,000 BTU","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003ePentair item \u003cstrong\u003e460730\u003c\/strong\u003e: MasterTemp 200 Natural Gas Pool and Spa Heater, 200,000 BTU. The MasterTemp High-Performance Heater offers smart features and an optional energy-saving Smart Bypass Valve Kit.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e460730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003ctd\u003eMasterTemp 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBTU\u003c\/th\u003e\n\u003ctd\u003e200,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger efficiency\u003c\/th\u003e\n\u003ctd\u003e84%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExchanger material\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeader material\u003c\/th\u003e\n\u003ctd\u003ePolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePool type\u003c\/th\u003e\n\u003ctd\u003eIn-Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarton weight\u003c\/th\u003e\n\u003ctd\u003e128 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e788379724054\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDocuments\u003c\/th\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/mastertemp-heater-manual-english.pdf\"\u003eInstallation and User's Guide - English (PDF)\u003c\/a\u003e; \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/archive\/mastertemp400-pool-and-spa-heater-installation-and-users-guide-french.pdf\"\u003eInstallation and User's Guide - French (PDF)\u003c\/a\u003e; \u003ca href=\"https:\/\/www.pentair.com\/content\/dam\/extranet\/nam\/pentair-pool\/residential\/heaters\/mastertemp\/manual\/archive\/mastertemp400-pool-and-spa-heater-installation-and-users-guide-spanish.pdf\"\u003eInstallation and User's Guide - Spanish (PDF)\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePentair reference\u003c\/th\u003e\n\u003ctd\u003ePentair Heaters and Heat Pumps catalog 2025-2026 p. 96; Pentair Heaters and Heat Pumps catalog 2021 p. 106; Pentair Heaters and Heat Pumps catalog 2020 p. 104; Pentair Heaters and Heat Pumps catalog 2019 p. 102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFeatures and benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSmart connectivity via the Pentair Automation Systems enables you to manage pool functions anytime, anywhere.\u003c\/li\u003e\n\u003cli\u003eFull-text digital display combines new functions and a user-friendly menu for easy operation and diagnostics.\u003c\/li\u003e\n\u003cli\u003eDigital connectivity with your pool's automation system and an advanced ignition control module with flame strength sensor help to ensure optimal heater performance.\u003c\/li\u003e\n\u003cli\u003eAlerts pushed to a smart device to keep you updated on heater performance and real-time status.\u003c\/li\u003e\n\u003cli\u003eOptional Smart Heater Bypass valve control diverts water flow when the heater isn't needed to help save up to 35% in yearly operational costs.*\u003c\/li\u003e\n\u003cli\u003eAvailable only in store from Pentair dealers or retail stores\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":49171793772763,"sku":"460730","price":3199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/460730_1__81108.1594060768.386.513__39591__45889.webp?v=1787607619"},{"product_id":"raypak-017371-digital-asme-206a-pool-heater-natural-gas-bronze-headers-copper-199-500-btu-b-r206a-en-c-50","title":"Raypak 017371 Digital ASME B-R206A-EN-C #50 Pool Heater, Natural Gas, 199,500 BTU, Copper Heat Exchanger, Bronze Headers","description":"\u003cdiv class=\"pps-details\"\u003e\n\u003cp\u003eRaypak item \u003cstrong\u003e017371\u003c\/strong\u003e: Digital ASME B-R206A-EN-C #50 pool heater, natural gas, 199,500 BTU. A natural gas ASME pool and spa heater with a copper heat exchanger, rated for elevations from 0 to 2000 ft.\u003c\/p\u003e\n\u003ch3\u003eProduct details\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePart number\u003c\/th\u003e\n\u003ctd\u003e017371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eRaypak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDescription (per Raypak)\u003c\/th\u003e\n\u003ctd\u003eUNIT-C\/P B-R206A-EN-C #50 ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUPC\u003c\/th\u003e\n\u003ctd\u003e840891041535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003ctd\u003e199,500 BTU\/h (58.4 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas type\u003c\/th\u003e\n\u003ctd\u003eNatural\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0-2000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat exchanger\u003c\/th\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e210 lb with stackless top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRaypak reference\u003c\/th\u003e\n\u003ctd\u003eRaypak Residential Pool \u0026amp; Spa Product Catalog RP-P-902-6 rev D p. 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Raypak Digital ASME 206A is the code-stamped version of the Digital atmospheric gas heater. Bronze headers and an ASME-certified copper fin-tube heat exchanger take the place of the polymer headers used on the residential model, for pools and spas where an ASME heater is required, typically commercial sites.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRelated items\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe propane ASME 206A is a different item number (017383).\u003c\/li\u003e\n\u003cli\u003eRaypak also lists item 017375 with the #51 orifice and item 017379 with the #52 orifice; on copper models Raypak gives #51 for 2,000 to 6,000 ft and #52 for 6,000 to 9,000 ft.\u003c\/li\u003e\n\u003cli\u003eThe cupronickel ASME 206A is a different item number (017399).\u003c\/li\u003e\n\u003cli\u003eOutdoor installation as shipped, using the stackless top packed with the heater. Indoor installation needs Raypak indoor stack kit 009838 and a vent to the outside, or the D-2 power vent kit (010744 for 120 V, 009832 for 240 V).\u003c\/li\u003e\n\u003cli\u003ePump flow between 20 and 100 GPM. Above 100 GPM Raypak calls for an external bypass valve.\u003c\/li\u003e\n\u003cli\u003eSome jurisdictions require a flow switch on ASME installations. Raypak offers kit 015889F (flange connection) or 015890F (NPT connection) for that.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak lists the Digital ASME series at 82% thermal efficiency.\u003c\/li\u003e\n\u003cli\u003eNatural gas supply pressure 6 in. WC minimum, 10.5 in. WC maximum. Gas connection 3\/4 in. NPT.\u003c\/li\u003e\n\u003cli\u003eASME heat exchanger: bronze headers and copper fin tubes, HLW-stamped, 100 PSIG maximum allowable working pressure, registered with the National Board.\u003c\/li\u003e\n\u003cli\u003eA 75 PSI pressure relief valve is included, shipped loose for the 3\/4 in. NPT port in the header.\u003c\/li\u003e\n\u003cli\u003eA ProTek Shield sacrificial assembly and its adapter are included, shipped loose for installation at the inlet connection. It protects the heat exchanger from galvanic corrosion.\u003c\/li\u003e\n\u003cli\u003eElectronic intermittent ignition lights the pilot and main burners automatically on a call for heat.\u003c\/li\u003e\n\u003cli\u003eDigital control with LCD display: pool and spa modes, adjustable setpoint, status and diagnostic messages. Remote-ready for two-wire or three-wire control systems.\u003c\/li\u003e\n\u003cli\u003eUnitherm Governor (thermostatic mixing valve) and a built-in automatic bypass valve in the inlet\/outlet header.\u003c\/li\u003e\n\u003cli\u003ePower 120 or 240 VAC, single phase, 60 Hz, through a dual-voltage transformer; Raypak states the heater is factory-wired for 240 VAC. Draws 4 A at 120 V or 2 A at 240 V. Not for 208 VAC.\u003c\/li\u003e\n\u003cli\u003eWater connections 2 in. slip, with CPVC unions. Right-hand as shipped; Raypak lists left-hand as an optional field change.\u003c\/li\u003e\n\u003cli\u003eCabinet 20 in. wide, 28 in. deep, 38 in. high; 40 in. to the top of the outdoor stackless top. Flue diameter 6 in.\u003c\/li\u003e\n\u003cli\u003eIn the carton: outdoor stackless (pagoda) top, two 2 in. CPVC union halves with O-rings, plastic finish flange for the gas line, bonding lug, pressure relief valve, and the ProTek Shield adapter with ProTek Shield, O-ring and wing nut.\u003c\/li\u003e\n\u003cli\u003eRaypak limited warranty for ASME models: one year parts and labor.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGood to know\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRaypak rates the input for elevations up to 2,000 ft and reduces it 4% for each 1,000 ft above sea level beyond that, so order the version built for your elevation.\u003c\/li\u003e\n\u003cli\u003eThe ProTek Shield is a wear item. Raypak says to replace it when its weight has dropped to about 40% of the original.\u003c\/li\u003e\n\u003cli\u003eSalt chlorinators and chemical feeders must be plumbed downstream of the heater. Raypak's water chemistry table allows up to 4,500 ppm salt.\u003c\/li\u003e\n\u003cli\u003eThis is the atmospheric ASME model. Raypak's Low NOx ASME heaters are the separate 207A to 407A models.\u003c\/li\u003e\n\u003cli\u003eGas, venting and electrical work must be done by a qualified installer or service agency and meet local codes. Raypak's warranty applies to heaters installed by a licensed service provider.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Raypak","offers":[{"title":"Default Title","offer_id":50608883826907,"sku":"017371","price":3573.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0641\/8343\/5483\/files\/61YiIFXHTuL._AC_SL1500.jpg?v=1791740852"}],"url":"https:\/\/premierpools.com\/collections\/natural-gas-heaters-parts.oembed","provider":"Premier Pool \u0026 Spa","version":"1.0","type":"link"}