Raypak 010744 D-2 Power Vent Kit, 120V (Convertible to 240V), for 206A, 207A, 266A, 267A and 268A Heaters
- Low stock - 2 items left
- Backordered, shipping soon
Raypak 010744 D-2 Power Vent Kit, 120V
Part # 010744 | Genuine Raypak accessory | For 206A, 207A, 266A, 267A and 268A electronic-ignition heaters
The D-2 Power Vent is a blower unit that sits on top of the heater and pushes the flue gases out through a 4 in. vent; on a retrofit the existing pagoda top or drafthood comes off first. It is Raypak's option for heaters that have to vent through a side wall or need a reduced vent pipe size. This kit is the smaller of the two sizes and leaves the factory wired for 120 V.
✅ Fits these Raypak models:
- Raypak 206A and 266A digital (electronic ignition) heaters
- Raypak 207A and 267A digital Low NOx heaters (Raypak dates the residential models to 2004 through 2023)
- Raypak 268A Professional Series heaters (the D-2 manual writes the model as 268)
- Raypak model 266, which an earlier revision of the 206A-406A manual lists together with the 266A
- Electronic ignition models only: Raypak does not list the D-2 for millivolt heaters
- The 336A, 337A, 406A, 407A and 408A take the larger kit, 010745
🔧 Details:
- In the box, per Raypak: D-2 Power Vent, collar adapter, 7/8 in. plastic grommet, adjustable 90 degree elbow with screen (the side-wall termination) and 4 in. flue adapter
- Blower motor: 120/240 V, 60 Hz, 1.95/1.0 A, 3200 RPM, in a plenum with a draft-proving switch and motor relay
- Wired at the factory for 120 V; the blower can be rewired for 240 V. The same kit wired for 240 V at the factory is 009832
- Vent connection: 4 in. collar. Category III vent pipe and a 4 in. gasket-to-gasket flue adapter are field-supplied, not in the kit
- Maximum vent run: 100 equivalent ft including the termination; each 90 degree elbow counts as 10 ft, each 45 degree elbow as 5 ft, and no more than four 90 degree elbows
- Needs at least 24 in. of clearance above the unit
- A wire harness connects the unit to the heater controls; the draft-proving switch has to close before the main gas valve can open
- Raypak states the D-2 is tested and certified to ANSI Z21.56, the standard for pool heaters
📌 Good to know:
- For a through-the-wall installation Raypak requires the screened elbow supplied in the kit to be the vent termination.
- Category I vent material such as B-vent must not be used with the D-2; it runs at positive vent pressure and needs Category III pipe.
- Raypak does not support common venting of positive-pressure vent systems; plan a separate Category III vent for the D-2.
- Installation involves gas venting and line-voltage wiring and must be done by a qualified installer following Raypak's D-2 manual (P/N 241243) and local code.
Check your heater's model and serial number before ordering.
Purchasing this item online may violate the manufacturer's policies and may not come with a Warranty. Beware of counterfeit or similar products that do not come with the same features.
Some examples of restricted products include Pentair's TradeGrade Series, Hayward's Expert Line Series, Maytronics' Active Line Series, and Polaris/Zodiac/Fluidra's Trade Series Exclusives.
📩 Contact us now if you are local and would like more information about installation or wish to purchase this item!
Due to Manufacturer Regulations, this item is only available locally. Please contact us if you are interested in purchasing.