Raypak 007374F Ignition Control-Kit

Raypak 007374F Ignition Control Kit (Hot Surface Ignition) for Hi Delta, Delta Limited, MVB and XTherm Heaters

007374F

Regular price$350.00
/
Shipping calculated at checkout.

Raypak 007374F Ignition Control Kit

Part # 007374F | Genuine Raypak replacement part | For Hi Delta 302 to 2342, Delta Limited, MVB and XTherm commercial heaters

This kit is the ignition control module for Raypak Hi Delta, Delta Limited, MVB and XTherm commercial heaters. These heaters light with a hot-surface igniter; the control runs the ignition sequence and uses the flame sensor to confirm the burners are lit. Raypak's parts-library photo shows a Fenwal automatic ignition control whose label says it must only be replaced with an identical part, Raypak kit 007374F.

✅ Fits these Raypak models:

  • Hi Delta 302, 402, 502, 652, 752 and 902, including the A and B versions of each size (built 1998 to 2017)
  • Hi Delta 992, 1262, 1532, 1802, 2002, 2072 and 2342, including the A and B versions (built 1999 to 2017)
  • Delta Limited 399, 499, 649, 749 and 899 (built 2002 to 2007)
  • Delta Limited 989, 1259, 1529, 1799, 1999, 2069 and 2339 (built 2002 to 2007)
  • MVB 503 to 2003 (built 2006 to 2013) and MVB 504 to 2004 (built 2007 to 2014) with the three-try ignition control
  • XTherm 1005, 1505 and 2005 (built 2008 to 2014) with the three-try ignition control

🔧 Details:

  • Raypak parts list name: Ignition Control (Ignition Control HSI Three Try on the MVB and XTherm lists).
  • The module label in Raypak's photo reads Fenwal automatic ignition control, 3 tries, 24 VAC input, for a 120 VAC hot-surface igniter.
  • The photo shows the kit as the control module with a wire harness, a separate lead wire, wire nuts, crimp terminals, mounting screws and cable ties.
  • On the Hi Delta and Delta Limited lists it sits with hot-surface igniter 007400F and flame sensor 006535F.

📌 Good to know:

  • Heaters fitted with the manual-reset ignition control take 009057F, not this kit. Raypak lists that version for the Hi Delta A and B models and the Delta Limited, and calls it the single-try control on the MVB and XTherm lists.
  • This is a commercial heater part. It is not listed for Raypak's residential pool heaters (206A to 406A, 207A to 407A, RP2100, Versa, 106A, 156A or Avia).
  • Ignition and gas controls should be replaced by a qualified service technician.

Check your heater's model and serial number before ordering.

Free 90-day returns. No restocking fee, prepaid label. Opened the box to check fit? Still a full refund. Details