Raypak 004817B Ignition Control Natural Gas For 106A Heater, Analog

Raypak 004817B Ignition Control, Natural Gas IID, for 106A Analog, RP2100 (1993-2003) and Versa Heaters

004817B

Regular price$185.00
/
Shipping calculated at checkout.

Raypak 004817B Ignition Control, Natural Gas IID

Part # 004817B | Genuine Raypak replacement part | For 106A analog, RP2100 and Versa natural gas heaters with electronic ignition

This is the ignition control module for Raypak natural gas heaters that light the pilot automatically (intermittent ignition, or IID) rather than keeping a standing pilot. Raypak's parts library names it Kit-Elec Ign W/O Lock; the W/Lock control, 004818B, is the one the parts lists give for propane units and for RP2100 Low NOx units. Raypak lists 004817B for the 106A analog above-ground heater and for a long line of older RP2100, Versa and Spa-Pak heaters.

✅ Fits these Raypak models:

  • Raypak 106A above-ground heater with analog control, natural gas (not the 156A)
  • Raypak RP2100 R185, R265, R335 and R405 with electronic ignition, natural gas (built 11/1993 to 10/1998)
  • Raypak RP2100 R185A, R265A, R335A and R405A atmospheric models with electronic ignition, natural gas (built 11/1998 to 10/2003)
  • Raypak Versa 185A to 405A (built 11/1986 to 10/1988) and Versa 185B to 405B and 185C to 405C (built 10/1988 to 11/1993) with electronic ignition, natural gas
  • Raypak Versa 155B/C (built 9/1991 to 6/2006), Versa 105A (10/1991 to 5/1999) and Versa 105B (1999 to 7/2006) with electronic ignition, natural gas
  • Raypak Versa 055A (built 5/1987 to 9/1989) and 055B (10/1990 to 4/2013) with electronic ignition, natural gas
  • Raypak Spa-Pak 053A and 053B (built 1984 to 1987), model 151 with electronic ignition (11/1980 to 12/1981) and model 153A (1984 to 2/1987)

🔧 Details:

  • Raypak parts library name: Kit-Elec Ign W/O Lock. The other control, 004818B, is Kit-Elec Ign W/Lock, and the R185A to R405A parts list calls it Ignition Control IID Lock
  • For natural gas units with electronic ignition. The parts lists give 004818B for propane IID units and for RP2100 Low NOx units

📌 Good to know:

  • Not used on the 156A, the digital 206A to 406A, the RP2100 R185B to R405B (built 10/2003 to 10/2004) or the 130A. Their parts lists show no ignition control of this kind (the 130A has its own direct-spark control, 011606F).
  • The 106A and 156A manual's troubleshooting chart includes checking that the high-tension wire is properly connected to the ignition module.
  • Gas ignition parts should be fitted and tested by a qualified service technician.

Check your heater's model and serial number before ordering.

Request a quote
Find It in the store:2-E-07-D

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.


Recently viewed