Raypak 005899F Rollout Switch. Fusible Link Thermal Cut-Off Fuse

Raypak 005899F Thermal Fuse (Flame Roll-Out Safety) for Atmospheric 206A-406A, 408A, 106A, 156A and RP2100 Heaters

005899F

Regular price$28.60
/
Shipping calculated at checkout.

Raypak 005899F Thermal Fuse (Flame Roll-Out Safety)

Part # 005899F | Genuine Raypak replacement part | For 206A to 406A, 408A, 106A, 156A and RP2100 atmospheric heaters

This thermal fuse is the flame roll-out safety on Raypak atmospheric gas heaters. Raypak describes it as a single-use fusible link: it opens when it overheats, which happens when the flue passages of the heat exchanger are badly restricted, and it has to be replaced before the heater will run again. Digital models report an open fuse as Rollout Sw Open.

✅ Fits these Raypak models:

  • Raypak 206A, 266A, 336A and 406A atmospheric heaters, digital and millivolt, built from 10/2004 (also the 266 and 399 named in the older parts list)
  • Raypak 408A Professional Series
  • Raypak 106A and 156A above-ground pool heaters (listed there as Roll-Out Safety Switch)
  • Raypak 130A (built 10/2005 to 4/2013)
  • Raypak RP2100 R185 to R405 (built 11/1993 to 10/1998) and the atmospheric R185A to R405A and R185B to R405B (built 11/1998 to 10/2004)
  • Raypak Versa 105A (built 10/1991 to 5/1999) and Versa 155B/C (built 9/1991 to 6/2006)

🔧 Details:

  • Single-use fusible link: it does not reset and has to be replaced once it has opened
  • Raypak names for the same part: Thermal Fuse, Roll-Out Safety Switch, Atmospheric Rollout Switch
  • Not for Low NOx heaters: the 207A to 407A and the Low NOx RP2100 models use roll-out switch 006035F

📌 Good to know:

  • Non-returnable: this fuse can burn out as soon as it is installed if the underlying problem, such as a blocked flue or a sooted heat exchanger, has not been fixed. Troubleshoot the heater before replacing the fuse.
  • If a new fuse burns out right away, the heater has a problem that another fuse will not fix. Heavy soot in the heat exchanger, or missing insulation in the combustion chamber, can open the fuse almost at once. The heater then needs service, and on an older heater it is worth comparing the cost of that repair with a replacement heater.
  • Raypak's troubleshooting for an open rollout circuit is to check for a blocked or sooted heat exchanger and, on atmospheric units, to replace the fusible link. The 106A and 156A manual also names flame roll-out and high winds as causes. Find and clear the cause before fitting a new fuse.
  • Work on the safety circuit of a gas heater is for a qualified service technician.

Check your heater's model and serial number before ordering.

Request a quote
Find It in the store:2-E-07-D, 2-E-07-D

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.