Arctic Spa HPt Error Code: Meaning and Fixes
An HPt code on your Arctic Spa's topside display means the spa did not pass its heater probe test. Every time the spa powers up it runs a short test mode, shown as tSt, and briefly fires the heater. If the high-limit probe does not sense the heater barrel warming up during that test, the spa stops and shows HPt.


Why it happens
- The spa was drained and refilled with cold water.
- The power went out.
- The supply voltage dropped (a brownout).
- The high-limit probe is not secured in place.
- A component has failed.
Fix 1: After a drain and refill
Very cold fill water can leave the probe unable to detect any temperature change, so the start-up test has to be bypassed.
- Turn the breaker to the spa off for 5 seconds, then turn it back on.
- When the topside control shows tSt, hold down the PUMP 3 button until you see 5.HPt scroll across the screen, then release the button.
- If the display now shows Stby (standby), press any button. The spa should start up.
- If the test will not bypass, the spa may need a software update. See Need help? below.
Extremely cold water: once the test is bypassed, the spa may go into freeze-protect mode and cycle on and off until the water reaches 50°F (10°C).
Fix 2: After a power outage or brownout
If the power went off, or the voltage dipped, a breaker reset is usually all it takes.
- Reset the breaker: switch it off for 5 seconds, then back on.
- The spa runs through tSt and then returns to normal operation.
If HPt comes back after you reset the breaker, work through the sections below.
When HPt or HL will not clear
The high-limit probe is rarely the problem. We service around 1,000 Arctic Spas and only need to replace this probe on about one spa a year. Before replacing it, pin down the symptoms: what is the spa doing that points to the probe?
Start here: which code, and how soon?
Reset the breaker and watch the display. Does the spa show HPt, or does it show HL right away, within a few minutes of being turned on?
HL within a few minutes: suspect pump 1
With an HL error it is more likely that pump 1 low speed or high speed is dead. When the spa calls for heat it turns on the heater and pump 1. If pump 1 does not start immediately, the heater overheats and throws the HL error.
- Check the amp draw for pump 1 on low speed and on high speed. Is it drawing the correct amps?
- Turn pump 1 on and off through low and high speed several times. If it does not start in low and go into high every time without error, pump 1 is likely the issue.
- If the amps are correct and pump 1 always starts with no issues, check for something blocking the suction side of pump 1.
- Try running the spa with no filters in at all to see if that clears the error.
Checking pump 1 for flow restrictions: see our guide, How to Clear a Hot Tub Air Lock: Spa Pump & Arctic Spas Guide.
Other causes of an HL code
HL can be a lot of things. If everything else is working, the most common is a heater relay stuck on. It can also be:
- Low water level letting air in through the filter to the pump (air lock)
- A stuck filter weir (air lock)
- Clogged filters
- A recent water change (air lock)
- Closed jets on pump 1, making it hard to clear heated water out of the heater
- A closed or partly closed valve on pump 1
- Something stuck in the wet end of pump 1
- A faulty heater probe
- A bad heater probe connection at the board
- A short on the board where the heater probe connects
- Pump 1 low speed hesitating, struggling to start, or not starting at all
Most likely: a stuck heater relay. When the relay sticks, the heater keeps heating after the pump stops, reaches about 118°F, and triggers the HL high-limit code. To confirm it, someone with a meter needs to take an amperage reading at the heater just as the heater is supposed to shut off (when the tub reaches its set temperature). With a stuck relay the heater keeps heating after the pump stops. It will overheat and can even boil the water for a few seconds.
Probe, heater and board tests
Work through these in order when HPt or HL keeps returning after a breaker reset.
Live 240 V: these checks are inside the main control box, and the voltage test is done with the power on. If you are not comfortable using a multimeter around live voltage, stop and see Need help? below.
Test 1: Check the high-limit probe connection at the main control box
- Disconnect the high-limit probe from the main control box.
- Clean the pins and re-seat the connection to the board 3 times.
- Reset the breaker.
Does the error code return?
If the code is gone, the connection was the problem. If it returns, go on to Test 2.
Test 2: Reconnect the old probe and test the heater
- Reconnect the old probe. It does not need replacing.
- Turn the set temperature down 2 degrees below the spa's current temperature so the heater turns OFF.
- With a multimeter, test the heater voltage by touching the meter leads to the heater connections on the main control board. The heater relay light is OFF when the heater is off.
- The heater leads must stay attached to the main board for this test.
Please note: one minute after the breaker is reset the spa goes into test mode (tSt) and energizes the heater for 5 seconds. If you read 240 V for 5 seconds and then it goes away, that is normal.
Is 240 V present at the heater when the heater is turned off?
Steady 240 V with the heater off means the heater is being powered when it should not be, which points to a heater relay stuck on. Next, check the processor card in Test 3.
Test 3: Check the processor card
- First, make sure the processor card is seated firmly on the motherboard.
If the code does not clear, try the following:
- The processor card is held by one screw. Remove the screw, then pull the processor card out.
- Clean the pins and re-seat the card 3 times.
- Reset the breaker.
Helpful videos
Need help?
If you purchased your spa from Premier Pool & Spa in Minnesota, text or call us at 952.368.6070.
Otherwise, you will need to contact your dealer for more assistance and to schedule service if needed, or contact Arctic Spas tech support at [email protected] or 1.800.309.1744.