Raypak 010060F Copper Tube Bundle for 266/266A, 266L/267A Pool Heaters (Polymer Headers)
010060F
Raypak item 010060F: Copper Tube Bundle, item 4-HP. A replacement copper tube bundle for the heat exchanger of Raypak 266/266A, 266L/267A and 267A pool and spa heaters, replacing the internal heat exchanger tubing.
Product details
| Part number | 010060F |
|---|---|
| Manufacturer | Raypak |
| Description (per Raypak) | Tube Bundle Copper (call-out 4-HP) |
| Fits Raypak models | 266/266A; 266L/267A; 267A |
| UPC | 840891019749 |
| Raypak reference | Raypak Residential Pool & Spa Product Catalog RP-P-902-6 rev D p. 21, 33; Raypak IPL 9100.56 Millivolt 206A-406A p. 5; Raypak IPL 241793 Digital 207A-407A p. 43 |
Send us your model and serial number and we will confirm fit before you order.
This tube bundle is the fin tube core of the heat exchanger: the tubes the pool water flows through between the inlet/outlet header and the return header. Raypak lists it separately from the two headers, so it can be replaced on its own.
Fit notes:
- Raypak 266A heaters, digital and millivolt, with polymer headers and a copper heat exchanger (model number ending in C), built from 10/2004.
- Raypak 267A digital Low NOx heaters with polymer headers and a copper heat exchanger (residential models built 2004 to 2023).
- Not for heaters with a cupronickel heat exchanger (model number ending in X); those take a cupronickel tube bundle (014931F on units built from 7/2013).
- Not for ASME heaters with bronze or cast-iron headers, which use a different tube bundle.
Included:
- Supplied with the heat exchanger baffles, a flange nut kit and 2 header O-ring gaskets. Raypak also lists these on their own: baffle 005261F, flange nut kit 008259F, O-ring gaskets 006713F (set of 2).
- The inlet/outlet header and the return header are separate parts and are not included.
Good to know:
- Raypak warns that the water flow or water chemistry problem that ruined a tube bundle has very likely damaged the bypass valve and the Unitherm Governor as well. It recommends replacing the Unitherm Governor and inspecting the bypass assembly at the same time.
- Copper and cupronickel tube bundles are not interchangeable. Match the bundle to the heater's model suffix.
- Replacing a tube bundle means taking the heat exchanger out of a gas heater; have a qualified service technician do the work.
Out of stock? Get a quote.
We can usually source this item from our suppliers. Leave your details and we will text or email you a quote, typically within one business day.
Free 90-day returns. No restocking fee, prepaid label. Opened the box to check fit? Still a full refund. Details
Find It in the store: