Raypak 010060F Tube Bundle 266/267 Polymer Kit
Raypak 010060F Tube Bundle 266/267 Polymer Kit

Raypak 010060F Copper Tube Bundle for 266/266A, 266L/267A Pool Heaters (Polymer Headers)

010060F

Regular price$900.00
/
Shipping calculated at checkout.

Raypak item 010060F: Copper Tube Bundle, item 4-HP. A replacement copper tube bundle for the heat exchanger of Raypak 266/266A, 266L/267A and 267A pool and spa heaters, replacing the internal heat exchanger tubing.

Product details

Part number 010060F
Manufacturer Raypak
Description (per Raypak) Tube Bundle Copper (call-out 4-HP)
Fits Raypak models 266/266A; 266L/267A; 267A
UPC 840891019749
Raypak reference Raypak Residential Pool & Spa Product Catalog RP-P-902-6 rev D p. 21, 33; Raypak IPL 9100.56 Millivolt 206A-406A p. 5; Raypak IPL 241793 Digital 207A-407A p. 43

Send us your model and serial number and we will confirm fit before you order.

This tube bundle is the fin tube core of the heat exchanger: the tubes the pool water flows through between the inlet/outlet header and the return header. Raypak lists it separately from the two headers, so it can be replaced on its own.

Fit notes:

  • Raypak 266A heaters, digital and millivolt, with polymer headers and a copper heat exchanger (model number ending in C), built from 10/2004.
  • Raypak 267A digital Low NOx heaters with polymer headers and a copper heat exchanger (residential models built 2004 to 2023).
  • Not for heaters with a cupronickel heat exchanger (model number ending in X); those take a cupronickel tube bundle (014931F on units built from 7/2013).
  • Not for ASME heaters with bronze or cast-iron headers, which use a different tube bundle.

Included:

  • Supplied with the heat exchanger baffles, a flange nut kit and 2 header O-ring gaskets. Raypak also lists these on their own: baffle 005261F, flange nut kit 008259F, O-ring gaskets 006713F (set of 2).
  • The inlet/outlet header and the return header are separate parts and are not included.

Good to know:

  • Raypak warns that the water flow or water chemistry problem that ruined a tube bundle has very likely damaged the bypass valve and the Unitherm Governor as well. It recommends replacing the Unitherm Governor and inspecting the bypass assembly at the same time.
  • Copper and cupronickel tube bundles are not interchangeable. Match the bundle to the heater's model suffix.
  • Replacing a tube bundle means taking the heat exchanger out of a gas heater; have a qualified service technician do the work.
Free 90-day returns. No restocking fee, prepaid label. Opened the box to check fit? Still a full refund. Details
Find It in the store:

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.