Raypak item 009832: D-2 Indoor Power Vent Kit, factory wired 240 VAC.

A power vent for indoor installations of Raypak 206A, 207A, 266A, 267A and 268 IID pool heaters, shipped loose for field installation and wiring.

Product details

Part number 009832
Manufacturer Raypak
Description (per Raypak) D-2: Power Vent - Indoor, IID Only; factory wired for 240V operation
Fits Raypak models 206/207 - 266/267/268 (240 VAC); 206A/267A (IID Only); 207A, 267A (240 VAC P/N)
UPC 840891018361
Raypak reference Raypak Residential Pool & Spa Product Catalog RP-P-902-6 rev D p. 47, 86; Raypak IPL 241793 Digital 207A-407A p. 12

Send us your model and serial number and we will confirm fit before you order.

In the box, per Raypak: D-2 Power Vent, collar adapter, 7/8 in. plastic grommet, adjustable 90 degree elbow with screen (the side-wall termination) and 4 in. flue adapter.

  • Blower motor: 120/240 V, 60 Hz, 1.95/1.0 A, 3200 RPM, in a plenum with a draft-proving switch and motor relay.
  • The blower can be rewired for 120 V. The same kit wired for 120 V at the factory is 010744.
  • The 336A, 337A, 406A, 407A and 408A take the larger kit: 009833 wired for 240 V or 010745 wired for 120 V.
  • Raypak model 266 is listed together with the 266A in an earlier revision of the 206A-406A manual. Raypak does not list the D-2 for millivolt heaters.
  • Vent connection: 4 in. collar. Category III vent pipe and a 4 in. gasket-to-gasket flue adapter are field-supplied, not in the kit.
  • Maximum vent run: 100 equivalent ft including the termination; each 90 degree elbow counts as 10 ft, each 45 degree elbow as 5 ft, and no more than four 90 degree elbows.
  • Needs at least 24 in. of clearance above the unit.
  • Mounting brackets are relocated when the unit goes on a 206A or 207A; that step is skipped on the 266A, 267A and 268A.
  • A wire harness connects the unit to the heater controls; the draft-proving switch has to close before the main gas valve can open.
  • Raypak states the D-2 is tested and certified to ANSI Z21.56.

For a through-the-wall installation Raypak requires the screened elbow supplied in the kit to be the vent termination. Category I vent material such as B-vent must not be used with the D-2; it runs at positive vent pressure and needs Category III pipe. Raypak does not support common venting of positive-pressure vent systems.

Installation involves gas venting and line-voltage wiring and must be done by a qualified installer following Raypak's D-2 manual (P/N 241243) and local code.