Raypak 009840 Indoor Stack Kit (Drafthood) with Inner Adapter Panel, 8" Vent, for 336A and 337A Pool Heaters
009840
Raypak item 009840: Indoor Stack Kit (Drafthood) with Inner Adapter Panel.
An indoor stack kit, including the inner adapter panel, for venting Raypak 336A and 337A pool heaters installed indoors.
Product details
| Part number | 009840 |
|---|---|
| Manufacturer | Raypak |
| Description (per Raypak) | Indoor Stack Kit (Includes inner adapter panel); Indoor Drafthood Kit (Includes inner stack adapter panel) |
| Fits Raypak models | 336A (206A-406A parts list); 337A (207A-407A parts list) |
| UPC | 840891017998 |
| Raypak reference | Raypak Residential Pool & Spa Product Catalog RP-P-902-6 rev D p. 26, 38; Raypak IPL 9100.56 Millivolt 206A-406A p. 7; Raypak IPL 241793 Digital 207A-407A p. 9, 46 |
Send us your model and serial number and we will confirm fit before you order.
This is the indoor drafthood for Raypak 336A and 337A gas pool and spa heaters; Raypak's manuals call it the indoor stack kit. It connects the heater to a vent pipe so the flue gases are carried out of the building. These heaters come with the outdoor stackless top only and Raypak lists the indoor stack as optional equipment, so an indoor installation needs this kit ordered separately.
- Covers 336A digital (electronic ignition), 336A millivolt (built 2004 to 2020) and 337A digital Low NOx heaters (Raypak dates the residential 337A to 2004 through 2023)
- Other cabinet sizes take a different kit: 009838 for the 206A and 207A, 009839 for the 266A and 267A, 009841 for the 406A, 407A and 408A
- Not for the earlier RP2100 heaters (R335A and R335B, built 1998 to 2004): Raypak lists indoor stack kit 006698 for those
Details
- In the box, per Raypak: 1 unpainted drafthood, 1 adapter plate, 3 mounting brackets (clips), 3 screws and the instructions
- Vent outlet (flue) diameter: 8 in. (203 mm)
- Overall height with the indoor drafthood in Raypak's dimension tables: 63 in. (1600 mm) on the 336A, 57 in. (1448 mm) on the 337A
- Drafthood shipping weight listed by Raypak: 19 lb (8.6 kg)
- Raypak's contents list for the kit has no vent pipe or vent cap
Good to know
Raypak calls for a Category I vent on the drafthood, recommends Type B double-wall pipe the same size as the drafthood outlet, and requires at least 5 ft of vertical vent above the outlet. An indoor heater also needs combustion and ventilation air openings; the heater manual gives the minimum sizes. Where the vent has to run through a side wall, Raypak offers the D-2 Power Vent for electronic-ignition heaters instead of this drafthood. Venting a gas heater is work for a qualified installer, following the heater manual and local code.
Out of stock? Get a quote.
We can usually source this item from our suppliers. Leave your details and we will text or email you a quote, typically within one business day.